The Dual-Loop Control System for Variable Frequency Power

نویسندگان

  • Liping Zhao
  • Wanying Yao
  • Lei Fan
چکیده

Abstract— In order to meet the demand of the signal test device of phase-sensitive, by modeling and simulating on the transient stability and load change resistance, the control stability of variable frequency power is increased with parameter configuration, increased phase margin and amplitude margin. Besides, using ARM embedded kernel control chip the dual variable frequency power is established with the current loop model and the voltage loop model to have a simulation test, furthermore, a PI control strategy was applied to control the voltage fluctuation and improve the dynamic performance as well as stability of the device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Simulation of a New DC Power Supply Based on Dual Bridge Matrix Converter

A conventional high power DC power supply systems consist of a three-phase diode rectifier followed by a high frequency converter to supply loads at regulated DC voltage. These rectifiers draw significant harmonic currents from the utility, resulting in poor input power factor. In this paper, a DC power supply based on dual-bridge matrix converter (DBMC) with reduced number of switches is p...

متن کامل

Load Frequency Control in Two Area Power System Using Sliding Mode Control

In this article, the sliding mode control of frequency load control of power systems is studied. The study areaconsists of a system of water and heat. First, a mathematical model of the proposed system disturbances ismade and then sliding control mode for frequency load control is provided. By the system simulation andsliding mode control, it can be shown that the damping of oscillations is wel...

متن کامل

REDUCTION OF INVERTER OUTPUT CURRENT RIPPLE IN CONNECTION OF FUEL CELL TO THE POWER NETWORK

In this paper, a method is introduced which reduces the harmonicdistortion of the inverter output current, connecting the fuelcell to the AC load. Using FUZZY LOGIC-PI (FLPI), the controllingmethod is engaged in optimum tuning of the PI controllercoefficients of this converter. This converter has only one DC-ACboost inverter and simultaneously has the task of increasingvoltage level and generat...

متن کامل

Modeling and Simulation of Variable Frequency Pump Control Fatigue Test Machine

High-speed maglev train is considered an ideal vehicle in the 21st Century, as an important part of the train, the travel mechanism bears and delivers a variety of vertical and horizontal alternating load in operation, it affects the operation safety of the train directly, so key components of the travel mechanism should under fatigue strength test by fatigue test machine.The paper proposed a v...

متن کامل

توسعه مدل حلقه کنترل بار– فرکانس نیروگاه ها با در نظرگرفتن ضریب دمپینگ توربین

Maintaining desired megawatt output of a generator unit is an essential role of Automatic Load-Frequency Control (ALFC) loop for secure operation of power system. In modeling this control loop, a major part concerns with the modeling of the mechanical behavior of turbine-generator. While, the efficiency of turbines normally depends on the speed they are operated, in most studies it is not inclu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011