Lead Pressure Loss in the Heat Exchanger of the Elsy Fast Lead- Cooled Reactor by Cfd Approach

نویسندگان

  • Alexandru Onea
  • Michael Böttcher
  • Dankward Struwe
چکیده

The present paper discusses the pressure loss through the spiral heat exchanger (HX) proposed in the ELSY (European-Lead cooled SYstem) project. An approach based on CFD (Computational Fluid Dynamics) using the commercial code ANSYS CFX has been used for exploring the flow through the HX. The HX consists of perforated double inner and double outer walls, as well as an innovative spiral design of the pipe bundle. Two investigation ways are considered, namely a detailed local approach by employing unit slice models and a simplified global approach. The unit slice models discretize accurately small parts of the HX, while the global models consider geometrical simplifications of the main HX components. ANSYS CFX was qualified for pressure loss simulations through perforated plates. At nominal conditions, the pressure loss estimated meets the requirements issued in the reactor design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of unsuitable operational conditions on the transient performance of a small hydrogen liquefier

Joule-Thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. Although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. In the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic Joule-Thomson cooling system...

متن کامل

Cost Effective Heat Exchanger Network Design with Mixed Materials of Construction

This paper presents a simple methodology for cost estimation of a near optimal heat exchanger network, which comprises mixed materials of construction. Intraditional pinch technology and mathematical programming it is usually assumed that all heat exchangers in a network obey a single cost model. This implies that all heat exchangers  in a network are of the same type and use the same mate...

متن کامل

Experimental and Numerical Analysis of Flow and Heat Transfer in a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant

A numerical and experimental investigation of flow and heat transfer in a gas- liquid Thermosyphon Heat Exchanger "THE" with built in heat pipes and aluminum plate fins for moderate Reynolds numbers has been carried out. It's module is composed of 6 rows and 15 columns copper pipes with aluminum plate fins with dimensions of 130cm height, 47cm width and  20cm depth. The tubes have been fill...

متن کامل

A numerical investigation of γ-Al2O3-water nanofluids heat transfer and pressure drop in a shell and tube heat exchanger

The effect of γ-Al2O3 nanoparticles on heat transfer rate, baffle spacing and pressure drop in the shell side of small shell and tube heat exchangers was investigated numerically under turbulent regime. γ-Al2O3-water nanofluids and pure water were used in the shell side and the tube side of heat exchangers, respectively. Since the properties of γ-Al2O3-water nanofluids were variable, they were ...

متن کامل

High Temperature Heat Exchanger and Component Test Laboratory – a Graded Approach

The Next Generation Nuclear Plant (NGNP) Project and the Nuclear Hydrogen Initiative (NHI) are U.S. Department of Energy programs that are responsible for the research, development, and testing of high-temperature gas-cooled nuclear reactor technologies and thermally driven hydrogen production methods. The two programs are related, in that the nuclear reactor will provide high-temperature heat,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012