Retention force of T-bar clasps for titanium and cobalt-chromium removable partial dentures.

نویسندگان

  • Renata Cristina Silveira Rodrigues
  • Ana Paula Macedo
  • Erica Miranda de Torres
  • Maria da Glória Chiarello de Mattos
  • Ricardo Faria Ribeiro
چکیده

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexibility of the Retentive Arm of Acetal Resin Clasp versus Cast Clasps- an in Vitro Study

Restoration of esthetics is an important factor to consider in the fabrication of a removable partial denture (RPD) . 1 Several types of polymers and metal alloys have been used in RPD construction. Frequently, RPD clasps made from the same alloy as the metal framework. The most common alloys used for clasps are cobalt-chromium (Co-Cr) alloy and gold and titanium alloys, although these may be u...

متن کامل

Comparison between Acetal Resin and Cobalt-chromium Removable Partial Denture Clasps: Effect on Abutment Teeth

Fabricating an esthetically pleasing removable partial denture while avoiding the unsightly display associated with conventional clasp assemblies presented a challenge to dentists. Among other techniques, this could be done using acetal resin clasps as simple and effective means of improving removable partial denture esthetics.1 Patients often cite lack of retention and poor esthetics as reason...

متن کامل

Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.

BACKGROUND/AIM Retentive force of removable partial denture (RPD) directly depends on elastic force of stretched retentive clasp arms (RCAs). During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profi...

متن کامل

An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.

STATEMENT OF PROBLEM The use of metal clasps on anterior teeth may cause esthetic problems. Recently, acetal resins have been used as an alternative tooth-colored denture clasp material to improve esthetics. However, there are few studies to support acetal resin use. PURPOSE The purpose of this in vitro study was to compare the retentive force and deformation of acetal resin and cobalt-chromi...

متن کامل

The abrasion of dental composite by cobalt-chromium clasps.

In cases where there are no suitable natural undercuts on the teeth which can be used to provide clasp retention for a partial denture artificial undercuts can be created by the application of a composite filling material. An in-vitro investigation was undertaken to assess the surface integrity of three different composite restorative materials following repeated cycles of movement of cobalt-ch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2008