The intra- and inter-assay variation of the indirect mixed antiglobulin reaction test: is a quality control suitable?

نویسندگان

  • C Bohring
  • W Krause
چکیده

The test most commonly used to detect sperm antibodies is the mixed antiglobulin reaction (MAR), standardized by the World Health Organization. The indirect MAR test detects soluble sperm antibodies in seminal plasma by using healthy donor spermatozoa as antigen. In this study we systematically investigated the influence of donor spermatozoa and the source of sperm antibodies upon the results of the indirect MAR test, and calculated the intra- and inter-assay variations. Using one individual seminal plasma and the same donor semen, results of the indirect MAR test are highly reproducible (low intra-assay variation). Two dimensions of inter-assay variation must be considered: (i) serial ejaculates of an individual donor may be used at different times; (ii) different donors may be applied to identical antibody sources. Donor spermatozoa strongly influenced the results of the indirect MAR test. Using multivariate statistical tests, highly significant main effects between the different donors (P < 0.001) and specific reciprocal effects between donor spermatozoa and seminal plasma samples (P < 0.001) were observed. The high inter-assay variation of the indirect MAR test will lead to incorrect results. There is urgent need of a reliable and reproducible test for sperm antibody detection to improve quality control of the methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limit of Detection of HEV RNA for Diagnosis of HEV Infection

ABSTRACT &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Background and Objectives: Diagnosis of hepatitis E virus (HEV) infection could be missed in some cases if serological tests are used solely. Molecular characterization of HEV is essential for diagnosis of acute and chronic HEV infections, and evaluating the chronic HEV infection status in immunocompromised patients. T...

متن کامل

ارزیابی بالینی نتایج آزمایش مار(MAR– Mixed Agglutination Reaction) و آزمایش تات (TAT – Tray Agglutination Test) در مردان نابارور

ABSTRACT: Of the antisperm immunoglobulins ,only antisperm surface IgA an IgGs are significant clinically because many fertile men have antisperm antibodies present in their sera. Since the necessity of one form of sperm surface antisperm test(specific)is felt in our country,and Immunobead is not popular here for its high cost,Mixed Antiglobulin Reaction test was studied in a population of inf...

متن کامل

ABO Hemolytic Disease Leading to Hyperbilirubinemia in Term Newborns: Value of Immunohematological Tests

Introduction ABO hemolytic disease of the newborn is most common cause of neonatal jaundice; previous studies have shown a poor correlation between serologic tests and clinical course in affected infants. The aim of this study was to identify the value of direct and indirect Coombs’ immunohematological tests, to identify the incidence of hemolytic disease in newborns (ABO-HDN). Methods : This  ...

متن کامل

طراحی و ارزیابی کیت آنتی بادی ضد کراتین [AKA] در بیماران آرتریت روماتویید

Background and purpose: Rheumatoid Arthritis (RA) is a systemic auto immune Rheumatoid diseases. Auto antibodies are detected in this disease, with diagnostic and prognostic properties. One of them is AKA which reacts with the fibrous keratin in epiderm and the stratum corneum of rat esophageal epithelium. Hence at first AKA – IFA kit was designed, then its sensitivety and specificity was me...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Human reproduction

دوره 14 7  شماره 

صفحات  -

تاریخ انتشار 1999