What is an acceptable false negative rate in the detection of prostate cancer?
نویسندگان
چکیده
Background In prostate cancer (PCa) screening men and their physicians aim to rule out the presence of potentially life threatening PCa. To date, prostate specific antigen (PSA) testing and systematic prostate biopsy (Bx)-in case of an elevated PSA-are still the main modes of PCa detection. Often uncertainty remains when a PSA-test is <3.0 ng/mL or a Bx shows a benign result, leading to the continuous repeating of procedures. Here we assess the potential consequences of false negatives by studying follow-up data of a purely PSA-based approach with applying sextant Bx, an approach considered to have a high risk of missing PCa diagnosis. Methods Our study population consisted of 19,970 men from the ERSPC project section Rotterdam, initially screened in 1993-1999. We assessed clinically significant Gleason ≥3+4 PCa (csPCa) diagnosis within the 4-year screening interval and subsequent screening round 4 years later in men having a PSA <3.0 ng/mL at initial screening (no Bx) and men with Bx (PSA >3.0 ng/mL), but no PCa detected at that time. In addition, we addressed PCa mortality and PCa diagnosis for men with a negative PSA test and negative Bx, who were retested every 4 years covering a 15-year follow-up. Results A total of 14,935 men had PSA <3.0 ng/mL in the initial screening round, of whom 75 (0.5%) were diagnosed with csPCa at a subsequent screening examination and 2 (<0.1%) in the 4-year screening interval. For 2,260 men with a previously negative Bx at first screening, the figures were 17 (0.8%) and 2 (0.1%) respectively. Indolent PCa (Gleason ≤3+3) was diagnosed in 312 (2%) men with PSA <3.0 ng/mL initially and 115 (5%) men with initial negative Bx. After a 15-year follow-up, 45 (0.3%) PCa deaths occurred in men with initially low PSA, and 29 men (0.2%) had metastasis. For men with negative Bx, 11 (0.5%) PCa deaths occurred and 4 (0.2%) experienced metastasis. Conclusions The false negative rates for men with PSA <3.0 ng/mL and negative sextant Bx are extremely low but not negligible. Proper risk stratification before deciding to biopsy is expected to hardly miss any clinical significant PCa diagnosis. This is especially relevant with the increased use of the relatively expensive multi-parametric magnetic resonance imaging (mpMRI) guided targeted Bx procedures.
منابع مشابه
بررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملSignal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملDetection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey
Objective(s): The aim of this study was to analyze detection rates and effectiveness of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests ...
متن کاملEvaluating the Effects of Separate and Concomitant Use of MK-2206 and Salinomycin on Prostate Cancer Cell Line
Background: Prostate cancer is known as one of the most prevalent health disorders in the male population globally. The aim of the current study was to evaluate the effects of separate and concomitant use of MK-2206 and salinomycin on prostate cancer cell line. Methods: The antitumor potential of separate and concomitant use of MK-2206 and salinomycin was evaluated in a panel of prostate ca...
متن کاملWhat is the most appropriate test in detecting prostate cancer in patients with intermediate prostate specific antigen levels?
Abstract Background: Regarding the variety of tests present for detecting and also screening prostate cancer and also bearing in mind the advantages and disadvantages of these tests we decided to re-evaluate these tests (total prostate specific antigen and all of its modifications) in detecting prostate cancer in men with intermediate serum PSAlevels. Methods: Following a cross se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2018