Edge effect correction for small planar Langmuir probes
نویسندگان
چکیده
Related Articles Contamination effects on fixed-bias Langmuir probes Rev. Sci. Instrum. 83, 113502 (2012) Performance of a permanent-magnet helicon source at 27 and 13MHz Phys. Plasmas 19, 093509 (2012) Langmuir probe diagnostics of an atmospheric pressure, vortex–stabilized nitrogen plasma jet J. Appl. Phys. 112, 063302 (2012) Revisiting plasma hysteresis with an electronically compensated Langmuir probe Rev. Sci. Instrum. 83, 093504 (2012) The effects of neutral gas heating on H mode transition and maintenance currents in a 13.56MHz planar coil inductively coupled plasma reactor Phys. Plasmas 19, 093501 (2012)
منابع مشابه
Particle-in-cell simulations of planar and cylindrical Langmuir probes: Floating potential and ion saturation current
Particle-in-cell and hybrid electron-Boltzmann simulations of planar and cylindrical Langmuir probes are compared with various probe theories. Floating potentials for planar and cylindrical probes are calculated and significant deviations from the typical approximation used for argon discharges of 5Te are shown. The interpretation of simulated ion saturation currents by the orbital motion limit...
متن کاملTemporal limits of a rapidly swept Langmuir probe
The finite, electrostatically achievable, temporal resolution of plasma properties from a turbulent discharge is limited by an array of effects wherein the theory of Langmuir probes breaks down. Formulations for the particle transit time, sheath formation time, plasma-probe resonance, polarization current, sheath capacitance, stray capacitance, and mutual capacitance effects are all evaluated f...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملDetailed Measurements of Poloidal Velocity of Density and Floating Potential Fluctuations in the Edge Plasma of the CASTOR Tokamak
The ion saturation current and floating potential are measured with high temporal (1 μs) and spatial (2.5 mm) resolutions within the edge plasma of CASTOR tokamak by two poloidally spaced radial arrays of Langmuir probes. The radial electric field and the phase velocity of plasma fluctuations are determined. It is found that radial profiles of both of these quantities are strongly sheared in th...
متن کاملComparison of Edge Fluctuation Measurements from PCI, BES, Langmuir Probes and Reflectometry on DIII–D
Phase contrast imaging (PCI), beam emission spectroscopy (BES), reflectometry, and Langmuir probes provide different but complementary measurements of the density fluctuations in the edge of the DIII–D tokamak plasma. In particular, the PCI is sensitive to modes with kθ kr, while the BES and probe response depends less on the angle of ~k⊥. On plasma discharges in which these diagnostics collect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012