Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry.

نویسندگان

  • Martin Schmidt
  • Uwe Dorwarth
  • Dietrich Andresen
  • Johannes Brachmann
  • Karl-Heinz Kuck
  • Malte Kuniss
  • Thorsten Lewalter
  • Stefan Spitzer
  • Stephan Willems
  • Jochen Senges
  • Claus Jünger
  • Ellen Hoffmann
چکیده

BACKGROUND Catheter ablation is used extensively with curative intention in atrial fibrillation. Radiofrequency ablation has long been a standard of care, while cryoballoon technology has emerged as a feasible approach with promising results. Prospective multicenter registry data referring to both ablation technologies in AF ablation therapy are lacking. METHODS Between January 2007 and August 2011, a total of 3,775 consecutive patients with symptomatic paroxysmal AF who underwent PV ablation in their respective centers were enrolled. The cohort was divided into 2 groups according to the ablation energy source used: cryoballoon ablation (group 1, n = 905 [24.0%], median age 63 years, 64.3% men) and RF ablation (group 2, n = 2870 [76.0%], median age 63 years, 62.7% men). Comorbidities and baseline clinical characteristics were similar in both groups. RESULTS Acute success rate was similar in both groups (97.5% in cryo vs 97.6% in RF; P = 0.81). Procedure times were similar, ablation and fluoroscopy times were higher in cryoballoon when compared to RF ablation. Overall complication rate was similar in cryo- (4.6%) and RF-ablation (4.6%; P = 1.0). Phrenic nerve palsy was more often in cryo versus RF ablation (2.1% in cryo vs 0.0% in RF; P < 0.001). Other complications were more common in RF compared to cryoablation (4.6% in RF vs 2.7% in cryo; P < 0.05). CONCLUSION RF ablation is the most widespread ablation method in Germany, but use of cryoballoon increased significantly. Procedure times were similar, but ablation and fluoroscopy times were longer in cryoballoon ablation. No significant differences were found in terms of acute success and overall complication rate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-Year Follow-Up after Contact Force Sensing Radiofrequency Catheter and Second-Generation Cryoballoon Ablation for Paroxysmal Atrial Fibrillation: A Comparative Single Centre Study

Background. There are little comparative data on catheter ablation of paroxysmal atrial fibrillation (AF) using the contact force radiofrequency (CF-RF) catheter versus the second-generation cryoballoon (CB2). Methods and results. This is a single center, retrospective, nonrandomized study of 98 patients with symptomatic, drug-refractory paroxysmal AF who underwent their first PVI ablation usin...

متن کامل

Randomised clinical trial of cryoballoon versus irrigated radio frequency catheter ablation for atrial fibrillation—the effect of double short versus standard exposure cryoablation duration during pulmonary vein isolation (CIRCA-DOSE): methods and rationale

INTRODUCTION Pulmonary vein isolation (PVI) is an effective therapy for paroxysmal atrial fibrillation (AF), but it has limitations. The two most significant recent advances have centred on the integration of real-time quantitative assessment of catheter contact force into focal radio frequency (RF) ablation catheters and the development of dedicated ablation tools capable of achieving PVI with...

متن کامل

Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial.

BACKGROUND Early recurrence of atrial fibrillation (ERAF) is common after radiofrequency catheter ablation for AF. We sought to determine the incidence and prognostic significance of ERAF after cryoballoon ablation. Moreover, the benefit of early reablation for ERAF after cryoballoon ablation is undetermined. METHODS AND RESULTS The Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP ...

متن کامل

Cryoballoon vs. open irrigated radiofrequency ablation for paroxysmal atrial fibrillation: long-term FreezeAF outcomes

BACKGROUND Effective treatment of paroxysmal atrial fibrillation (AF) is essential for reducing the risk of stroke and heart failure. Cryoballoon (CB) ablation has been developed as an alternative to the use of radiofrequency (RF) energy for electrical isolation of the pulmonary veins. Herein, we provide long-term data regarding the efficacy of CB ablation in comparison to RF. METHODS FreezeA...

متن کامل

First-line catheter ablation of paroxysmal atrial fibrillation: outcome of radiofrequency vs. cryoballoon pulmonary vein isolation.

AIMS First-line ablation prior to antiarrhythmic drug (AAD) therapy is an option for symptomatic paroxysmal atrial fibrillation (PAF); however, the optimal ablation technique, radiofrequency (RF), or cryoballoon (CB) has to be determined. METHODS AND RESULTS The FREEZE Cohort Study compares RF and CB ablation. Treatment-naïve patients were documented in the FREEZEplus Registry. Periprocedural...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 25 1  شماره 

صفحات  -