Artifacts and diagnostic pitfalls in positron emission tomography-magnetic resonance imaging.

نویسندگان

  • Claudia Martinez-Rios
  • Raymond F Muzic
  • Frank P DiFilippo
  • Lingzhi Hu
  • Christian Rubbert
  • Karin A Herrmann
چکیده

Introduction Positron emission tomography-magnetic resonance (PETMR) is a new hybrid imaging modality that has recently been introduced in clinical practice for oncologic imaging and is increasingly being used in various clinical indications. PET-MR unifies the complementary capabilities of magnetic resonance imaging (MRI) and PET in a single imaging modality. Excellent anatomical and morphologic information with high soft tissue resolution and contrast from MRI and the best possible molecular, functional, and physiological information fromPET are complementary andhave the potential to provide maximum diagnostic information in a single procedure. However, the incremental diagnostic value of PET-MRover the current standard imaging procedures in various clinical scenarios is still under investigation. Initial results indicate that PET-MR is particularly promising in oncologic diseases and is at least equivalent to PET-computed tomography (PETCT) in lesion detection. Besides the hope for improved clinical and diagnostic performance, there are further expected benefits of PET-MR over current conventional imaging techniques: PET-MR harbors the potential to improve the patients’ workflow and save the patient and the administrative organization the implications of numerous appointments for multiple imaging procedures. As such “one-stop-shop” imaging modality, PET-MRmaybemore time efficient than conventional imaging techniques, such as CT or even PET-CT. Furthermore, there is the potential to decrease the overall radiation exposure to the patient from diagnostic imaging; an issue that gains particular relevance in the world of pediatric patients and young adult patients with a need for repetitive imaging follow-up. Although, both PET and MRI have been well-established individual standalone imaging modalities for decades, the marriage of the 2 components in 1 device came along with significant hardware and software adjustments. Inherent to such adjustments is the risk and likelihood for new imaging effects and artifacts that need to be addressed to guarantee appropriate, reliable, and reproducible diagnostic interpretation. The fact that today’s commercially available models of PET-MR devices operate with significant vendor-dependent technical differences adds complexity to these systems. Differences in the technical approach to PET-MRI increases the necessity to identify, improve, or if not possible at least, describe technology-related imaging artifacts and effects and bring these effects to the attention of the ultimate user of this new technology. The present review first aims to provide an overview over the most common artifacts and pitfalls encountered with PET-MR. It describes their imaging characteristics and discusses the technical background and potential ways of mitigating these issues. It focuses on the potential clinical implications of these artifacts to increase the awareness of these challenges and helps avoid interpretation errors in the clinical use. Secondly, this review addresses the challenges in workflow and in setting up appropriate functional and practical imaging protocols for the use of this complex combined hybrid imaging modality. It will provide suggestions and examples of practical approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

P28: Neuroimaging in Anxiety Disorders

In recent years, the development of neuroimaging techniques such as high-resolution magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), positron emission tomography (PET), or single photon emission tomography (SPECT) has promoted the identification of structural and functional characteristics underlying mental disorders to a great extent. In anxiety disorders, recent...

متن کامل

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Seminars in roentgenology

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2014