Measurement Error Estimation for Capacitive Voltage Transformer by Insulation Parameters

نویسندگان

  • Bin Chen
  • Lin Du
  • Kun Liu
  • Xianshun Chen
  • Fuzhou Zhang
  • Feng Yang
چکیده

Measurement errors of a capacitive voltage transformer (CVT) are relevant to its equivalent parameters for which its capacitive divider contributes the most. In daily operation, dielectric aging, moisture, dielectric breakdown, etc., it will exert mixing effects on a capacitive divider’s insulation characteristics, leading to fluctuation in equivalent parameters which result in the measurement error. This paper proposes an equivalent circuit model to represent a CVT which incorporates insulation characteristics of a capacitive divider. After software simulation and laboratory experiments, the relationship between measurement errors and insulation parameters is obtained. It indicates that variation of insulation parameters in a CVT will cause a reasonable measurement error. From field tests and calculation, equivalent capacitance mainly affects magnitude error, while dielectric loss mainly affects phase error. As capacitance changes 0.2%, magnitude error can reach −0.2%. As dielectric loss factor changes 0.2%, phase error can reach 5′. An increase of equivalent capacitance and dielectric loss factor in the high-voltage capacitor will cause a positive real power measurement error. An increase of equivalent capacitance and dielectric loss factor in the low-voltage capacitor will cause a negative real power measurement error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grey Relational Analysis for Insulation Condition Assessment of Power Transformers Based Upon Conventional Dielectric Response Measurement

Conventional dielectric response measurement techniques, for instance, recovery voltage measurement (RVM), frequency domain spectroscopy (FDS) and polarization–depolarization current (PDC) are effective nondestructive insulation monitoring techniques for oil-impregnated power transformers. Previous studies have focused mainly on some single type of dielectric measurement method. However, the co...

متن کامل

Application of Ann Methods for Instrument Transformer Correction in Transmission Line Protection

Current and voltage transformers influence the criterion values measurement particularly during disturbances in the system. Certain construction limitations of instrument transformers may in some cases cause maloperation or substantial delay in tripping of the protective relays. Current transformer saturation and discharging of the capacitive voltage transformer’s internal energy during short c...

متن کامل

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Correlation of Dga, Uhf Pd Measurement and Vibration Data for Power Transformer Monitoring

Reliability of electrical energy networks depends on quality and availability of electrical equipment like power transformers. Local failures inside their insulation may lead to catastrophic breakdowns. To prevent destroying events power transformers are e.g. tested on partial discharge (PD) activity. As testing is just snapshot information about transformers condition, permanent online monitor...

متن کامل

Statistical Analysis of Electrical and Mechanical Breakdown Stress for Insulation Performance in High Voltage Power Transformer

Original scientific paper In electrical power system, variety of solid, liquid and gaseous materials are used for insulation target to protect the incipient failure inside the high voltage power transformers. The insulation is practically ended when the insulation system has become fragile enough to flourish cracks under the electrical and mechanical stresses to which it is subjected. The elect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017