Enzyme-linked immunosorbent assay spin amplification technique for herpes simplex virus antigen detection.

نویسندگان

  • F J Michalski
  • M Shaikh
  • F Sahraie
  • S Desai
  • L Verano
  • J Vallabhaneni
چکیده

A comparative study of herpes simplex virus diagnosis by standard cell culture and a new hybrid test (enzyme-linked immunosorbent assay spin amplification technique) was done on 300 specimens. The new test was found to be equally sensitive and specific, much less expensive to perform, and to report all results in 48 h.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an enzyme-linked immunosorbent assay for the detection of herpes simplex virus antigen.

An enzyme-linked immunosorbent assay (ELISA) kit for herpes simplex virus developed by Ortho Diagnostic Systems, Inc., was evaluated. In phase I experiments, 263 clinical specimens from genital lesions were extracted into serum-free medium and then tested by ELISA for herpes simplex virus antigen. The results were compared with those obtained by conventional viral culture. Of 83 specimens, 65 w...

متن کامل

Standardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.

An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...

متن کامل

Performance of two commercial enzyme-linked immunosorbent assay kits using recombinant glycoprotein G2 antigen for detection of herpes simplex virus type 2 specific antibodies.

For 93 stored serum samples tested by HerpeSelect2 and the Euroimmun enzyme-linked immunosorbent assay for detection of herpes simplex virus type 2-specific immunoglobulin G antibodies, the concordance of positive and negative results was 100%. Moreover, all the results that were equivocal by HerpeSelect2 (negative by Euroimmun) were confirmed as being negative by a Western blot assay.

متن کامل

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 1986