Improvement in Diagnosis of Histoplasma Meningitis by Combined Testing for Histoplasma Antigen and Immunoglobulin G and Immunoglobulin M Anti-Histoplasma Antibody in Cerebrospinal Fluid

نویسندگان

  • Karen C Bloch
  • Thein Myint
  • Luke Raymond-Guillen
  • Chadi A Hage
  • Thomas E Davis
  • Patty W Wright
  • Felicia C Chow
  • Laila Woc-Colburn
  • Raed N Khairy
  • Alan C Street
  • Tomotaka Yamamoto
  • Amanda Albers
  • L Joseph Wheat
چکیده

Background Central nervous system (CNS) histoplasmosis is a life-threatening condition and represents a diagnostic and therapeutic challenge. Isolation of Histoplasma capsulatum from cerebrospinal fluid (CSF) or brain tissue is diagnostic; however, culture is insensitive and slow growth may result in significant treatment delay. We performed a retrospective multicenter study to evaluate the sensitivity and specificity of a new anti-Histoplasma antibody enzyme immunoassay (EIA) for the detection of IgG and IgM antibody in the CSF for diagnosis of CNS histoplasmosis, the primary objective of the study. The secondary objective was to determine the effect of improvements in the Histoplasma galactomannan antigen detection EIA on the diagnosis of Histoplasma meningitis. Methods Residual CSF specimens from patients with Histoplasma meningitis and controls were tested for Histoplasma antigen and anti-Histoplasma immunoglobulin G (IgG) and immunoglobulin M (IgM) antibody using assays developed at MiraVista Diagnostics. Results A total of 50 cases and 157 controls were evaluated. Fifty percent of patients with CNS histoplasmosis were immunocompromised, 14% had other medical conditions, and 36% were healthy. Histoplasma antigen was detected in CSF in 78% of cases and the specificity was 97%. Anti-Histoplasma IgG or IgM antibody was detected in 82% of cases and the specificity was 93%. The sensitivity of detection of antibody by currently available serologic testing including immunodiffusion and complement fixation was 51% and the specificity was 96%. Testing for both CSF antigen and antibody by EIA was the most sensitive approach, detecting 98% of cases. Conclusions Testing CSF for anti-Histoplasma IgG and IgM antibody complements antigen detection and improves the sensitivity for diagnosis of Histoplasma meningitis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Diagnosis of Acute Pulmonary Histoplasmosis by Combining Antigen and Antibody Detection.

BACKGROUND Acute pulmonary histoplasmosis can be severe, especially following heavy inoculum exposure. Rapid diagnosis is critical and often possible by detection of antigen, but this test may be falsely negative in 17% of such cases. Antibody detection by enzyme immunoassay (EIA) may increase sensitivity and permit the measurement of immunoglobulin M (IgM) and immunoglobulin G (IgG) classes of...

متن کامل

A histoplasma capsulatum-specific IgG1 isotype monoclonal antibody, H1C, to a 70-kilodalton cell surface protein is not protective in murine histoplasmosis.

Monoclonal antibodies to Histoplasma capsulatum can modify pathogenesis. We now show that monoclonal antibody H1C to a 70-kDa antigen increases intracellular fungal growth and reduces macrophage nitric oxide release but has no effect on fungal burden or survival in murine infection. This further demonstrates the complexities of host-pathogen interactions.

متن کامل

False-positive Aspergillus galactomannan assay in solid organ transplant recipients with histoplasmosis.

Post-transplantation histoplasmosis may be acquired via inhalation, may result from endogenous reactivation, or may be derived from the allograft. The Histoplasma and Aspergillus enzyme-linked immunoassays are increasingly being relied upon for rapid diagnosis of fungal infections, especially in immunocompromised patients. We describe 4 cases of solid organ transplant recipients who had histopl...

متن کامل

Histoplasma capsulatum prosthetic valve endocarditis with negative fungal blood cultures and negative histoplasma antigen assay in an immunocompetent patient.

We report a case of Histoplasma capsulatum endocarditis in which Histoplasma antigen assay and fungal blood cultures were negative. The diagnosis was made by microscopic examination and culture of the excised valve. Histoplasma capsulatum should be considered in the differential diagnosis of culture-negative endocarditis in regions where it is endemic and in travelers.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 66  شماره 

صفحات  -

تاریخ انتشار 2018