Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography.

نویسندگان

  • Sarah Muscat
  • Nicola McKay
  • Stuart Parks
  • Ewan Kemp
  • David Keating
چکیده

PURPOSE To assess the repeatability and interoperator and intersession reproducibility of central corneal thickness (CCT) measurements made by a commercially available optical coherence tomography (OCT) system. METHODS Intersession and interoperator reproducibility and repeatability were defined according to the guidelines of the British Standards Institution and examined in a control group of 14 normal subjects. An in-house computer program was used to evaluate central corneal thickness from these scans. RESULTS The coefficient of interoperator reproducibility was 0.18%, whereas that for intersession reproducibility was 1.11%. Wilcoxon analysis (5% level of significance) showed that there was no statistically significant difference between scans acquired during different sessions or by different operators. Coefficients of repeatability were all less than 3%. The average CCT was 526 +/- 28 microm (SD) and the range of normal CCT between 5th and 95th percentiles was 498 to 576 microm. CONCLUSIONS Although the commercially available OCT scanner was designed for retinal imaging, with a few minor modifications, the system may be used to image the anterior segment. Previous studies have shown that OCT measurements correlate well with those from conventional techniques, and it has the added advantage of being a noncontact technique. This study further demonstrates that the OCT measurements show a high degree of repeatability and reproducibility. Thus, OCT is emerging as a promising tool for evaluation of CCT in the clinical setting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography.

PURPOSE To determine the repeatability and reproducibility of central and peripheral corneal pachymetry mapping with anterior segment-optical coherence tomography (AS-OCT). METHODS An observational cross-sectional study involving two groups: 27 healthy eyes and 20 eyes with keratoconus. Each subject underwent scanning sessions with AS-OCT to determine intraobserver repeatability, interobserve...

متن کامل

Post-Mortem Corneal Thickness Measurements with a Portable Optical Coherence Tomography System: a Reliability Study

The purpose of this study was to determine the repeatability and reproducibility of post-mortem central corneal thickness (CCT) measurements by using a real-time, portable optical coherence tomography (OCT) system on an animal model, and to prospectively evaluate the time-course of post-mortem changes in CCT. Forty-six ocular globes of sheep (Ovis aries) were analyzed with a portable spectral-d...

متن کامل

Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry.

PURPOSE To assess the intraoperator repeatability and interoperator reproducibility of central corneal thickness measurements by the Pentacam Scheimpflug imaging system (Oculus) and the optical low-coherence reflectometer (OLCR) pachymeter (Haag-Streit) and to compare them with those of ultrasound (US) pachymetry. SETTING Assaf Harofe Medical Center Ophthalmology Outpatient Clinic, Zerifin, I...

متن کامل

Reliability of RTVue, Visante, and Slit-Lamp Adapted Ultrasonic Pachymetry for Central Corneal Thickness Measurement

PURPOSE To evaluate reliability of Fourier-domain optical coherence tomography (OCT) (RTVue), time-domain OCT (Visante), and slit-lamp adapted ultrasonic pachymetry (SL-US) in the measurement of central corneal thickness (CCT). MATERIALS AND METHODS Thirty healthy volunteers visited our clinic 3 times and fifty eyes were measured by one physician. RTVue and Visante were randomly performed, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2002