Percutaneous steerable robotic tool delivery platform and metal microelectromechanical systems device for tissue manipulation and approximation: closure of patent foramen ovale in an animal model.

نویسندگان

  • Nikolay V Vasilyev
  • Andrew H Gosline
  • Evan Butler
  • Nora Lang
  • Patrick J Codd
  • Haruo Yamauchi
  • Eric N Feins
  • Chris R Folk
  • Adam L Cohen
  • Richard Chen
  • David Zurakowski
  • Pedro J del Nido
  • Pierre E Dupont
چکیده

BACKGROUND Beating-heart image-guided intracardiac interventions have been evolving rapidly. To extend the domain of catheter-based and transcardiac interventions into reconstructive surgery, a new robotic tool delivery platform and a tissue approximation device have been developed. Initial results using these tools to perform patent foramen ovale closure are described. METHODS AND RESULTS A robotic tool delivery platform comprising superelastic metal tubes provides the capability of delivering and manipulating tools and devices inside the beating heart. A new device technology is also presented that uses a metal-based microelectromechanical systems-manufacturing process to produce fully assembled and fully functional millimeter-scale tools. As a demonstration of both technologies, patent foramen ovale creation and closure was performed in a swine model. In the first group of animals (n=10), a preliminary study was performed. The procedural technique was validated with a transcardiac hand-held delivery platform and epicardial echocardiography, video-assisted cardioscopy, and fluoroscopy. In the second group (n=9), the procedure was performed percutaneously using the robotic tool delivery platform under epicardial echocardiography and fluoroscopy imaging. All patent foramen ovales were completely closed in the first group. In the second group, the patent foramen ovale was not successfully created in 1 animal, and the defects were completely closed in 6 of the 8 remaining animals. CONCLUSIONS In contrast to existing robotic catheter technologies, the robotic tool delivery platform uses a combination of stiffness and active steerability along its length to provide the positioning accuracy and force-application capability necessary for tissue manipulation. In combination with a microelectromechanical systems tool technology, it can enable reconstructive procedures inside the beating heart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy

This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...

متن کامل

Magnetic resonance-guided placement of atrial septal closure device in animal model of patent foramen ovale.

BACKGROUND Percutaneous closure of the patent foramen ovale (PFO) is usually performed under x-ray in combination with ultrasound guidance. We tested the feasibility of applying magnetic resonance (MR) guidance for percutaneous closure of PFO in an animal model, thus avoiding the disadvantage of ionizing radiation. METHODS AND RESULTS Real-time MRI with radial or spiral k-space filling (15 fr...

متن کامل

Myocarditis due to pandemic influenza A (H1N1).

1. Cruz-Gonzalez I, Solis J, Inglessis-Azuaje I, Palacios IF. Foramen oval permeable: situación actual. Rev Esp Cardiol. 2008;61:738-51. 2. Wahl A, Meier B, Haxel B, Nedeltchev K, Arnold M, Eicher E, et al. Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism. Neurology. 2001;57:1330-2. 3. Windecker S, Wahl A, Chatterjee T, Garachemani A, Eberli FR, Seiler C, et...

متن کامل

Triple percutaneous patent foramen ovale closure

Percutaneous patent foramen ovale (PFO) closure is mainly performed for secondary prevention of presumed paradoxical embolism. Since a residual shunt has been associated with recurrent events, complete PFO closure is desirable. We report the first case of ultimately successful percutaneous PFO closure using successively 3 Amplatzer PFO devices.

متن کامل

Patent foramen ovale and cryptogenic stroke: the hole story.

Despite 3 recent randomized clinical trials, the management of patients with cryptogenic stroke and patent foramen ovale remains unsettled. The primary results of Evaluation of the STARFlex Septal Closure System in Patients with a Stroke and/or Transient Ischemic Attack due to Presumed Paradoxical Embolism Through a Patent Foramen Ovale (CLOSURE), Percutaneous Closure of Patent Foramen Ovale in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2013