The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques

نویسندگان

  • Tomohisa Furuya
  • Satoru Sugimoto
  • Chie Kurokawa
  • Shuichi Ozawa
  • Kumiko Karasawa
  • Keisuke Sasai
چکیده

To evaluate the dosimetric impact of respiratory breast motion and daily setup error on whole breast irradiation (WBI) using three irradiation techniques; conventional wedge (CW), field-in-field (FIF) and irregular surface compensator (ISC). WBI was planned for 16 breast cancer patients. The dose indices for evaluated clinical target volume (CTV(evl)), lung, and body were evaluated. For the anterior-posterior (AP) respiratory motion and setup error of a single fraction, the isocenter was moved according to a sine function, and the dose indices were averaged over one period. Furthermore, the dose indices were weighted according to setup error frequencies that have a normal distribution to model systematic and random setup error for the entire treatment course. In all irradiation techniques, AP movement has a significant impact on dose distribution. CTV(evl)D(95) (the minimum relative dose that covers 95 % volume) and V(95) (the relative volume receiving 95 % of the prescribed dose) were observed to significantly decrease from the original ISC plan when simulated for the entire treatment course. In contrast, the D(95), V(95) and dose homogeneity index did not significantly differ from those of the original plans for FIF and CW. With regard to lung dose, the effect of motion was very similar among all three techniques. The dosimetric impact of AP respiratory breast motion and setup error was largest for the ISC technique, and the second greatest effect was observed with the FIF technique. However, these variations are relatively small.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

Radiobiological and physical effects of patient setup errors during whole breast irradiation

Background: The dose-related effects of patient setup errors on bio-physical indices were evaluated for the conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques (WBI). Materials and Methods: The treatment plans of 10 patients receiving left WBI were retrospectively selected for evaluation. The bio-physical effects of dose variations were evaluated by shifting the...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

Performance evaluation of field-in-field technique for tangential breast irradiation.

Conventional hard or dynamic wedge systems are commonly applied to reduce the dose inhomogeneity associated with whole breast irradiation. We evaluated the dosimetric benefits of the field-in-field (FIF) technique by comparing it with the electronic compensator (EC), Varian enhanced dynamic wedge (EW) and conventional hard wedge (HW) techniques. Data were obtained from 12 patients who had under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013