Effect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: An analytical approach

نویسندگان

  • Ehsan Rajabi-Jaghargh
  • Kranthi K Kolli
  • Lloyd H Back
  • Rupak K Banerjee
چکیده

BACKGROUND Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high practical importance. METHODS In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δp-Q, curves for three different percentage area blockages corresponding to moderate (64%), intermediate (80%), and severe (90%) stenoses. Stenosis is considered to be axisymmetric consisting of three different sections namely converging, throat, and diverging regions. Analytical expressions for pressure drop are obtained for each of these regions separately. Using this approach, effects of lesion length and GW insertion on the mean translesional pressure drop and its component (loss due to momentum change and viscous loss) are analyzed. RESULTS AND CONCLUSION It is observed that for a given percent area stenosis (AS), increase in the throat length only increases the viscous loss. However, increase in the severity of stenosis and GW insertion increase both loss due to momentum change and viscous loss. GW insertion has greater contribution to the rise in viscous loss (increase by 2.14 and 2.72 times for 64% and 90% AS, respectively) than loss due to momentum change (1.34% increase for 64% AS and 25% decrease for 90% AS). It also alters the hyperemic pressure drop in moderate (48% increase) to intermediate (30% increase) stenoses significantly. However, in severe stenoses GW insertion has a negligible effect (0.5% increase) on hyperemic translesional pressure drop. It is also observed that pressure drop in a severe stenosis is less sensitive to lesion length variation (4% and 14% increase in Δp for without and with GW, respectively) as compared to intermediate (10% and 30% increase in Δp for without and with GW, respectively) and moderate stenoses (22% and 48% increase in Δp for without and with GW, respectively). Based on the contribution of pressure drop components to the total translesional pressure drop, it is found that viscous losses are dominant in moderate stenoses, while in severe stenoses losses due to momentum changes are significant. It is also shown that this simple analytical solution can provide valuable information regarding interpretation of coronary diagnostic parameters such as fractional flow reserve (FFR).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterizing momentum change and viscous loss of a hemodynamic endpoint in assessment of coronary lesions.

Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance ...

متن کامل

Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study

BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true s...

متن کامل

Effects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses.

This study gains insight on the nature of flow blockage effects of small guidewire catheter sensors in measuring mean trans-stenotic pressure gradients Deltap across significant coronary artery stenoses. Detailed pulsatile hemodynamic computations were made in conjunction with previously reported clinical data in a group of patients with clinically significant coronary lesions before angioplast...

متن کامل

Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation.

The pressure-flow characteristics of 100 left circumflex stenoses in 10 chronically instrumented unsedated dogs were studied under resting conditions and during pharmacological coronary vasodilation. At rest, the pressure loss (deltaP) due to a stenosis and arterial flow velocity (V) were related by the equation, deltaP = FV + SV2, where F is the coefficient of pressure loss due to viscous fric...

متن کامل

Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis.

To evaluate the local hemodynamic effects of coronary artery balloon angioplasty, computational fluid dynamics was applied to representative stenoses geometry post-angioplasty (minimal lesion diameter d(m) = 1.8mm which produced 64% mean area stenoses) based on a group of patients and measured values of coronary flow reserve (CFR) returning to a normal range (3.6+/-0.3). The computations were a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2011