Automated flow rate calculations based on digital analysis of flow convergence proximal to regurgitant orifices.

نویسندگان

  • P M Vandervoort
  • D H Thoreau
  • J M Rivera
  • R A Levine
  • A E Weyman
  • J D Thomas
چکیده

OBJECTIVES The purpose of the study was to develop and validate an automated method for calculating regurgitant flow rate using color Doppler echocardiography. BACKGROUND The proximal flow convergence method is a promising approach to quantitate valvular regurgitation noninvasively because it allows one to calculate regurgitant flow rate and regurgitant orifice area; however, defining the location of the regurgitant orifice is often difficult and can lead to significant error in the calculated flow rates. To overcome this problem we developed an automated algorithm to locate the orifice and calculate flow rate based on the digital Doppler velocity map. METHODS This algorithm compares the observed velocities with the anticipated relative velocities, cos psi/2 pi r2. The orifice is localized as the point with maximal correlation between predicted and observed velocity, whereas flow rate is specified as the slope of the regression line. We validated this algorithm in an in vitro model for flow through circular orifices with planar surroundings and a porcine bioprosthesis. RESULTS For flow through circular orifices, flow rates calculated on individual Doppler maps and on an average of eight velocity maps showed excellent agreement with true flow, with r = 0.977 and delta Q = -3.7 +/- 15.8 cm3/s and r = 0.991 and delta Q = -4.3 +/- 8.5 cm3/s, respectively. Calculated flow rates through the bioprosthesis correlated well but underestimated true flow, with r = 0.97, delta Q = -10.9 +/- 12.5 cm3/s, suggesting flow convergence over an angle > 2 pi. This systematic underestimation was corrected by assuming an effective convergence angle of 212 degrees. CONCLUSIONS This algorithm accurately locates the regurgitant orifice and calculates regurgitant flow rate for circular orifices with planar surroundings. Automated analysis of the proximal flow field is also applicable to more physiologic surfaces surrounding the regurgitant orifice; however, the convergence angle should be adjusted. This automated algorithm should make quantification of regurgitant flow rate and regurgitant orifice area more reproducible and readily available in clinical cardiology practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the proximal flow convergence method. Calculation of orifice area in patients with mitral stenosis.

BACKGROUND It has been proposed recently that measuring the flow convergence region proximal to an orifice by Doppler flow mapping can provide a means of calculating regurgitant flow rate. Although verified in experimental models, this approach is difficult to validate clinically because there is no ideal gold standard for regurgitant flows in patients. However, this method also can be used to ...

متن کامل

Impact of finite orifice size on proximal flow convergence. Implications for Doppler quantification of valvular regurgitation.

Analysis of velocity acceleration proximal to a regurgitant valve has been proposed as a method to quantify the regurgitant flow rate (Qo). Previous work has assumed inviscid flow through an infinitesimal orifice, predicting hemispheric isovelocity shells, with calculated flow rate given by Qc = 2 pi rN2vN, where vN is user-selected velocity of interest and rN is the distance from that velocity...

متن کامل

Dynamics of mitral regurgitant flow and orifice area. Physiologic application of the proximal flow convergence method: clinical data and experimental testing.

BACKGROUND The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implicati...

متن کامل

A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study.

While color Doppler flow mapping has yielded a quick and relatively sensitive method for visualizing the turbulent jets generated in valvular insufficiency, quantification of the degree of valvular insufficiency has been limited by the dependence of visualization of turbulent jets on hemodynamic as well as instrument-related factors. Color Doppler flow imaging, however, does have the capability...

متن کامل

A New Method for Noninvasive Quantification of Valvular Regurgitation Based on Conservation of Momentum

The noninvasive Doppler assessment of regurgitant volume from jet size is limited by the fundamental inequality of jet volume and regurgitant volume and by the dependence of jet dimensions on driving pressure and instrument settings for a given flow volume. Therefore, this study addresses the hypothesis that an equation could be derived from basic physical principles to quantify regurgitant vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1993