Characterization and validation of a pharmacokinetic model for controlled-release oxycodone.

نویسندگان

  • J W Mandema
  • R F Kaiko
  • B Oshlack
  • R F Reder
  • D R Stanski
چکیده

1. Oxycodone is a strong opioid agonist that is currently available in immediate-release (IR) formulations for the treatment of moderate to severe pain. Recently, controlled-release (CR) oxycodone tablets were developed to provide the benefits of twice-a-day dosing to patients treated with oxycodone. The purpose of this investigation was to develop and validate a pharmacokinetic model for CR oxycodone tablets in comparison with IR oxycodone solution. 2. Twenty-four normal male volunteers were enrolled in a single-dose, randomized, analytically blinded, two-way crossover study designed to compare the pharmacokinetics of two 10 mg CR oxycodone tablets with 20 mg IR oxycodone oral solution. Pharmacokinetic models describing the oxycodone plasma concentration vs time profiles of CR tablets and IR solution were derived using NONMEM version IV. The predictive performance of the models was assessed by comparison of predicted oxycodone plasma concentrations with actual oxycodone plasma concentrations observed in a separate group of 21 volunteers who received repeated doses of IR and CR oxycodone for 4 days. 3. The unit impulse disposition function of oxycodone was best described by a one-compartment model. Absorption rate of the IR solution was best described by a mono-exponential model with a lag time, whereas absorption rate of the CR tablet was best described using a bi-exponential model. The absorption profile of the CR tablets was characterized by a rapid absorption component (t1/2abs = 37 min) accounting for 38% of the available dose and a slow absorption phase (t1/2abs = 6.2 h) accounting for 62% of the available dose. Two 10 mg tablets of oral CR oxycodone hydrochloride were 102.7% bioavailable relative to 20 mg of IR oxycodone hydrochloride oral solution. The population model derived after administration of a single dose accurately predicted both the mean and range of oxycodone concentrations observed during 4 days of repeated dosing. The mean prediction error was 2.7% with a coefficient of variation of 54%. 4. The absorption characteristics of CR oxycodone tablets should allow effective plasma concentrations of oxycodone to be reached quickly and for effective concentrations to be maintained for a longer period after dosing compared with the IR oral solution. The CR dosage form has pharmacokinetic characteristics that permit 12 hourly dosing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices

The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...

متن کامل

Design and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices

The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...

متن کامل

Slow drug delivery decreased total body clearance and altered bioavailability of immediate- and controlled-release oxycodone formulations.

Oxycodone is a commonly used analgesic with a large body of pharmacokinetic data from various immediate-release or controlled-release formulations, under different administration routes, and in diverse populations. Longer terminal half-lives from extravascular administration as compared to IV administration have been attributed to flip-flop pharmacokinetics with the rate constant of absorption ...

متن کامل

Design and in vivo evaluation of oxycodone once-a-day controlled-release tablets

The aim of present study was to design oxycodone once-a-day controlled-release (CR) tablets and to perform in vitro/in vivo characterizations. Release profiles to achieve desired plasma concentration versus time curves were established by using simulation software and reported pharmacokinetic parameters of the drug. Hydroxypropyl methylcellulose (HPMC) 100,000 mPa·s was used as a release modifi...

متن کامل

Comparing the Effect of Tampering on the Oral Pharmacokinetic Profiles of Two Extended-Release Oxycodone Formulations with Abuse-Deterrent Properties.

OBJECTIVE Oxycodone DETERx® is an extended-release (ER), microsphere-in-capsule abuse-deterrent-formulation designed to retain its extended-release properties following tampering or misuse (e.g., chewing, crushing). This study assessed the safety and pharmacokinetics of orally administered intact and crushed Oxycodone DETERx® capsules compared with intact and crushed reformulated OxyContin® tab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of clinical pharmacology

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 1996