Clinical validation of a second-generation fructosamine assay.

نویسندگان

  • W T Cefalu
  • A D Bell-Farrow
  • M Petty
  • C Izlar
  • J A Smith
چکیده

The serum fructosamine assay, used to monitor short-term clinical glycemic control, reportedly has several technical drawbacks. However, technical improvements have resulted in a new second-generation assay of fructosamine. We evaluated this second-generation assay (from Roche Diagnostics) in 529 nondiabetic and diabetic patients and found a highly significant correlation with results of the first-generation assay (r = 0.91, P less than 0.001). Use of the second-generation assay with samples from patients classified on the basis of glycemic control according to their glycohemoglobin (GHb) values, enabled us to discriminate between the nondiabetics, diabetics with "good/moderate" control (i.e., GHb less than 10%), and diabetics with "poor" control (GHb greater than or equal to 10%). We evaluated the validity of the second-generation assay to assess short-term glycemic control in 23 non-insulin-dependent diabetic patients who participated for 10 weeks in an intensive intervention program designed to rapidly normalize the clinical glycemic profile. Results correlated significantly with the one-week average capillary blood glucose concentration (CBG) and with the three-week average CBG in all 23 patients. In addition, the second-generation fructosamine assay results demonstrated a significant decrease at each week of study, as did the average CBG. Results of the first- and second-generation assays correlated significantly at each week of study. GHb correlated significantly with both the second- (r = 0.78, P less than 0.001) and first-generation fructosamine assay results (r = 0.77, P less than 0.001) for the baseline blood samples of the intervention study, but this correlation decreased (to r = 0.35, P = 0.09 and r = 0.34, P = 0.09, respectively) by the conclusion of the study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assay of serum fructosamine that minimizes standardization and matrix problems: use to assess components of biological variation.

Methodological problems with the assay of fructosamine in serum--standardization, matrix effects, and dependence on buffer pH--have been minimized with a method involving colorimetric assay of each specimen and subsequent re-assay after standard addition of 1-deoxy-1-morpholinofructose. Absorbance at optimum wavelength of 540 nm varies linearly with fructosamine concentration to at least 5.5 mm...

متن کامل

Chemistry of the fructosamine assay: D-glucosone is the product of oxidation of Amadori compounds.

The chemistry of the fructosamine assay was studied by using the Amadori compound, N alpha-formyl-N epsilon-fructose-lysine (fFL), an analog of glycated lysine residues in protein. Previously (Clin Chem 1993;39:2460-5), we reported that free lysine was formed from fFL at 70% yield during incubation with alkaline nitroblue tetrazolium (NBT) under the conditions routinely used for the fructosamin...

متن کامل

Relative potency of commercial calibrators for fructosamine, and their effect on measurements of fructosamine in serum.

The protein-based secondary standardsfor serum fructosamine in a commercial test kit (Roche Diagnostics) have recently been modified by the manufacturer. Under certain assay conditions, the new calibrator gave significantly greater serum fructosamine values than those obtained with the originally supplied calibrator. However, for 20-4, samples and absorbance measurements at 10 and 15 mm, hereaf...

متن کامل

Influence of timing in the fructosamine assay.

The fructosamine assay, based on the measurement of the reducing activity in serum at alkaline pH, provides an index of protein glycation. The reducing activity is expressed in equivalents of 1-deoxy-1-morpholinofructose (DMF) by direct comparison with the activity either of this synthetic compound or with a secondary protein standard calibrated against DMF. This study reports the influence of ...

متن کامل

Technical performance evaluation of BM/Hitachi 747-200 serum fructosamine assay.

The technical performance of serum fructosamine assay as a short-term index of diabetic control was evaluated by using the BM/Hitachi 747-200 Automatic Analyzer (Boehringer Mannheim Corp). Intra- and interassay precisions (CV) were <2%. Linearity was confirmed up to 1000 micromol/L. Lipemia, produced artificially or from hypertriglyceridemia in vivo, did not interfere with measurement of serum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 1991