Bayesian analysis supports use of ambulatory blood pressure monitors for screening.

نویسندگان

  • F Elijovich
  • C L Laffer
چکیده

To assess whether there is a role for ambulatory blood pressure monitoring (ABPM) in screening for hypertension, we conducted Bayesian analysis of office blood pressure (OBP) as a diagnostic "test" in populations with different prior probabilities (PP) of hypertension. OBP was considered a positive test if systolic blood pressure was greater than 140 mm Hg or diastolic pressure was greater than 90 mm Hg. Chosen daytime ABPM cutoffs for a "gold standard" diagnosis of hypertension were systolic pressure of 139 and diastolic pressure of 88 mm Hg. Sensitivity and specificity of OBP were determined in 72 patients with established hypertension (PP = 1). After 3 weeks off therapy, OBP was 168 +/- 3/101 +/- 1 and ABPM was 151 +/- 2/94 +/- 1 mm Hg. Systolic ABPM was in the normotensive range in 17 patients and diastolic in 15 patients. OBP was falsely positive in 14 and 15 of these patients, respectively. Thus, sensitivity and specificity of OBP were 0.8909 and 0.1765 (systolic) and 0.9825 and 0 (diastolic). These data cannot be extrapolated to populations with lower PPs for use of Bayes' theorem. Hence, we calculated sensitivity and specificity for PP = 0 from published series of ABPM in normotensive subjects and used our measurements and these calculations in arithmetic interpolations for populations with PP 0.1-0.9. Sigmoid relations between PP and predictability of hypertension by a positive OBP were disclosed by use of Bayes' theorem. Their best-fit cubic polynomials predict that an elevated OBP will misdiagnose hypertension 46-50% of the time in a general population (PP = 0.2) but only 8-9% in a specialty practice (PP = 0.9).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of pulse interval timing in ambulatory blood pressure measurement

Blood pressure (BP) monitors rely on pulse detection. Some blood pressure monitors use pulse timings to analyse pulse interval variability for arrhythmia screening, but this assumes that the pulse interval timings detected from BP cuffs are accurate compared with RR intervals derived from ECG. In this study we compared the accuracy of pulse intervals detected using an ambulatory blood pressure ...

متن کامل

Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use.

OBJECTIVE(S) We compared a convenient, cuffless, wrist-type ambulatory blood pressure monitoring (ABPM) device (BPro) and a standard arm-type ABPM monitor under ambulatory conditions. METHODS Fifty normotensive and prehypertensive volunteers who had no interarm differences in BP were enrolled. The wrist and arm monitors were attached to the left wrist and the right arm, respectively, and prov...

متن کامل

How Accurate Are Home Blood Pressure Devices in Use? A Cross-Sectional Study

BACKGROUND Out of office blood pressure measurements, using either home monitors or 24 hour ambulatory monitoring, is widely recommended for management of hypertension. Though validation protocols, meant to be used by manufacturers, exist for blood pressure monitors, there is scant data in the literature about the accuracy of home blood pressure monitors in actual clinical practice. We performe...

متن کامل

Evaluation of noninvasive blood pressure monitoring devices Spacelabs 90202 and 90207 versus resting and ambulatory 24-hour intra-arterial blood pressure.

This study evaluated the accuracy of blood pressure values provided by the Spacelabs 90202 and 90207 devices in comparison with intra-arterial recording in 19 subjects at rest and in nine subjects in ambulatory conditions (Oxford method). At rest Spacelabs monitors reflected intra-arterial systolic blood pressure values very closely but overestimated to a considerable extent intra-arterial dias...

متن کامل

Cost-effectiveness of ambulatory blood pressure: a reanalysis.

Accurate diagnosis of hypertension and prognosis for future cardiovascular events can be enhanced through the use of 24-hour ambulatory blood pressure monitoring. It has been suggested that the use of ambulatory monitoring as a secondary screening for hypertension might be cost-effective. Many needed studies that are related to the calculation of cost-effectiveness for ambulatory monitoring hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hypertension

دوره 19 2 Suppl  شماره 

صفحات  -

تاریخ انتشار 1992