Non-invasive estimate of cardiac output during exercise based on impedance cardiography and oxygen uptake in the elderly.
نویسندگان
چکیده
OBJECTIVE This study assessed the agreement between cardiac output (Q) measurements generated by two indirect methods and their applicability in 54 men and 77 women (aged 60-90). METHODS The subjects performed a cardiopulmonary test with incremental to maximal exercise on a cycle-ergometer. "Q" was estimated based on oxygen uptake and on impedance cardiography at 50% and 100% of the maximal workload (Wmax) reached during the test. The limits of agreement and mean differences (biases) were estimated using the methodology proposed by Bland-Altman, whereas the relationship between the methods was analyzed by linear regression and intra-class correlation (ICC). RESULTS For the load equivalent do 50% of Wmax, the bias between the means of the two methods was -0.58 L x min-1 (6.3% smaller for the impedance measurement) and the limit of agreement was +/- 2.54 L x min-1 (24.7%). At 100% of Wmax, the bias was 1.03 L x min-1 (8.5% greater for the impedance measurement) with a limit of agreement of +/- 3.35 L x min-1 (27.6%). ICC values and the regression curves obtained between the methods were: Qimp=1.82+0.75Q VO2 (r(2)=0.765, p<0.001; ICC=0.727, p<0.01) at 50% Wmax; and Qimp=0.93+1.00Q VO2 (r(2)=0.755, p<0.001; ICC=0.796, p<0.01) at 100% Wmax. CONCLUSION These results suggest that there is a good agreement between the two methods for the measurement of Q during exercise in the elderly, which is compatible with the findings of similar studies with young subjects.
منابع مشابه
Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.
Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subj...
متن کاملCardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.
1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...
متن کاملRespiratory muscle unloading improves leg muscle oxygenation during exercise in patients with COPD.
BACKGROUND Respiratory muscle unloading during exercise could improve locomotor muscle oxygenation by increasing oxygen delivery (higher cardiac output and/or arterial oxygen content) in patients with chronic obstructive pulmonary disease (COPD). METHODS Sixteen non-hypoxaemic men (forced expiratory volume in 1 s 42.2 (13.9)% predicted) undertook, on different days, two constant work rate (70...
متن کاملCardiovascular and oxygen uptake kinetics during sequential heavy cycling exercises.
The purpose of the present study was to assess the relationship between the rapidity of increased oxygen uptake (VO2) and increased cardiac output (CO) during heavy exercise. Six subjects performed repeated bouts on a cycle ergometer above the ventilatory threshold (approximately 80% of peak VO2) separated by 10-min recovery cycling at 35% peak VO2. VO2 was determined breath-by-breath and CO wa...
متن کاملImpedance cardiography for monitoring changes in cardiac output.
Impedance Cardiography (ICG) is a non invasive method useful for continuous monitoring of cardiac output but, it still has not found wide usage for measuring cardiac output in clinics and research. Most studies focused on comparing the cardiac output measured at rest with reference methods. In the present study we evaluated the validity of ICG against Doppler Echocardiography (DE) in measuring ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 88 1 شماره
صفحات -
تاریخ انتشار 2007