Sensitive and selective time-gated luminescence detection of hydroxyl radical in water.

نویسندگان

  • Sarah E Page
  • Kyle T Wilke
  • Valérie C Pierre
چکیده

A terbium probe for the selective time-gated detection of hydroxyl radical is presented. This probe demonstrates high sensitivity with an 11.0-fold increase in time-gated luminescence intensity for an hour-long exposure to hydroxyl radical concentration in the femtomolar range, and high selectivity for HO* over other reactive oxygen species.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A europium(III) chelate as an efficient time-gated luminescent probe for nitric oxide.

The first Eu(3+) chelate-based luminescent probe specific for nitric oxide (NO) has been designed and synthesized for highly sensitive and selective time-gated luminescence detection of NO. Based on the probe, a time-gated luminescence imaging technique was developed for imaging the endogenous NO production in living plant cells/tissues.

متن کامل

A long-lived luminescence and EPR bimodal lanthanide-based probe for free radicals.

We developed a novel spin-labeled terbium complex Tb(3+)/cs124-DTPA-TEMPO (1) by covalently labeling a nitroxide radical on the terbium complex for monitoring free radicals of various areas. This lanthanide complex probe shows a high EPR signal which resulted from the nitroxide radical moiety, and is weakly luminescent which resulted from the intramolecular quenching effect of the nitroxide rad...

متن کامل

An amine/imine functionalized microporous MOF as a new fluorescent probe exhibiting selective sensing of Fe3+ and Al3+ over mixed metal ions

Nowadays metal-organic frameworks with multiple luminescent centers are very fascinating as multifunctional luminescent material because of their luminescence properties, which could be systematically tuned by deliberate use of organic ligands and metal ions. In this research, we explored a microporous mixed-ligand MOF for highly selective and sensitive detection of metal ions. A two-fold inter...

متن کامل

Dual-emissive nanoarchitecture of lanthanide-complex-modified silica particles for in vivo ratiometric time-gated luminescence imaging of hypochlorous acid.

We have developed a ratiometric time-gated luminescence sensory system for in vivo imaging of hypochlorous acid (HClO) by preparing a dual-emissive nanoarchitecture of europium- and terbium-complex-modified silica nanoparticles. The design of this nanoarchitecture is based on our new finding that the strong, long-lived luminescence of the β-diketonate-Eu3+ complex can be rapidly and selectively...

متن کامل

Development of a novel lysosome-targetable time-gated luminescence probe for ratiometric and luminescence lifetime detection of nitric oxide in vivo † †Electronic supplementary information (ESI) available: Experimental details for the syntheses of TRP-Tb3+ and TRP-NO, and supplementary figures. See DOI: 10.1039/c6sc03667h Click here for additional data file.

Rapid, multiplexed, sensitive and specific identification and quantitative detection of nitric oxide (NO) are in great demand in biomedical science. Herein, a novel multifunctional probe based on the intramolecular LRET (luminescence resonance energy transfer) strategy, TRP-NO, was designed for the highly sensitive and selective ratiometric and luminescence lifetime detection of lysosomal NO. B...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chemical communications

دوره 46 14  شماره 

صفحات  -

تاریخ انتشار 2010