AB290. SPR-17 Prosthesis insertion into segmented biomechanics simulation models
نویسندگان
چکیده
Objective: Biomechanical simulation requires accurate representation of the geometry of the structures to be studied. Specifically, when simulating the interaction of implanted prosthetics with surrounding tissues, the geometric and mechanical properties of the prosthesis and the surrounding tissues need to be adequately represented. The present work describes methods for inserting test prostheses into magnetic resonance imaging (MRI) derived geometric models of the pelvic floor structures, in order to create realistic simulation models. Methods: We modified an existing public domain image analysis software tool to allow placement and segmentation of arbitrarily shaped 3D objects into the output segmented geometry of a pelvic MRI image dataset. The tool was applied to create composite segmented geometry and 3D models of the MRI derived pelvic floor structures with the inserted prostheses in the intended anatomic locations, suitable for biomechanical simulation model creation. Results: Segmentations of the organs in the source pelvic MRI datasets were created, showing the segmented embedded prostheses in the planned location. Three dimensional reconstructions of the segmented datasets were generated, which were viewable from multiple angles, and the ability to turn on and off all tissue and prosthesis layers was demonstrated. Conclusions: We created a software application for inserting prostheses into segmented MRI based datasets. The output segmentations were suitable for input into a soft-tissue simulation tool suite, which generated simulation results suitable for analysis. This tool has the potential to enable patient specific, iterative surgical planning of prolapse repair strategies. Funding Source(s): None
منابع مشابه
Lumbar total disc replacement: a numerical study.
AIM The aim of this study was to evaluate the biomechanical effects of the Maverick(R) disc prosthesis at the implanted and adjacent level by the finite element (FE) method. MATERIALS AND METHODS A 3D FE model of the L3-L5 segment was built. To simulate the different physiological movements (flexion, extension, lateral bending, axial rotation) pure moments of 10 Nm were applied. To evaluate t...
متن کاملDynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject
The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...
متن کاملUse of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report.
Eight implants were placed in the posterior part of the mandible using computer-generated stereolithographic templates. Preoperative implant simulation was done on a 3D computer model created by reformatted computerized tomography data. The surgeon and the prosthodontist positioned the simulated implants in the most favorable position addressing all concerns with regard to anatomy, biomechanics...
متن کاملDesign and numerical simulation of surface plasmon resonance (SPR) skin pressure sensor based on graphene grating-sheet modifications
This article has no abstract.
متن کاملBiomechanical simulation of needle insertion into cornea based on distortion energy failure criterion.
PURPOSE This paper is mainly about biomechanical behavior of needle insertion into cornea, and proposes a failure criterion to simulate the insertion process which has attracted considerable attention due to its importance for the minimally invasive treatment. METHODS In the process of needle insertion into cornea, tiny and complex insertion force is generated due to contact between needle an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2016