Biocompatibility and cytotoxicity study of nanophotonic rigid gas permeable contact lens material

نویسنده

  • M Tomić
چکیده

Since materials on nanoscale have different characteristics from materials on macro scale their biocompatibility should be precisely and specifically investigated. Fullerenes, the third carbon allotrope, are one of the most used nanomaterials. The least stable and the most common is fullerene C60. One of the main disadvantages of fullerene is its low solubility in water. In order to make it soluble, it must be functionalized with polar groups such as –OH and –COOH. From all the water soluble fullerenes the most important ones are those with –OH groups attached named fullerols. We have developed new materials for contact lenses by adding fullerene (C60) and fullerol (C60(OH)24) into PMMA. The aim of our investigation was to compare the influences of those materials on aqueous solutions similar to tear film. For the analysis of the solutions we used opto-magnetic imaging and IR spectroscopy. The acquired spectrums were commented and compared with the standard contact lens material, which was analyzed by the same methods. The ISO 10993 cytotoxicity test on extract of nanophotonic material with incorporated C60 was done as well. This research contributes to better understanding of the biocompatibility of new rigid gas permeable contact lens materials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact lens rehabilitation following repaired corneal perforations

BACKGROUND Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. METHOD Eyes that had undergone repair for corneal perforating injuries with or wit...

متن کامل

Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system

PURPOSE We evaluated the usefulness of commercially available materials for protecting the cornea from drying during vitrectomy with a wide-angle viewing system. METHODS THREE VITREORETINAL SURGEONS EVALUATED FUNDUS VISIBILITY DURING VITRECTOMY ON THE IMAGES OF FIVE STUDY MATERIALS USED ON THE CORNEA: balanced saline solution, a viscoelastic agent, a vitrectomy contact lens, a rigid gas perme...

متن کامل

[Hybrid material contact lens in keratoconus and myopic astigmatism patients].

PURPOSE To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM) and rigid-gas-permeable (RGP), in patients with regular myopic astigmatism and with keratoconus. METHODS A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus) was condu...

متن کامل

Correction of astigmatism with contact lenses.

Contact lens correction of astigmatism is reviewed. According to literature data, rigid gas permeable lenses are the lenses of choice in correction of irregular and high astigmatism. The crucial advantage of rigid gas permeable lenses is clear vision and stable correction of astigmatism. Soft toric lenses ensure quick adaptation and comfort. The most prominent disadvantage of soft toric contact...

متن کامل

AFM in mode Peak Force applied to the study of un-worn contact lenses.

Contact lenses (CLs) are of common use and the biocompatibility, topography and mechanical properties of the used materials are of major importance. The objective of this contribution is to apply the AFM in mode Peak Force to obtain surface topography and mechanical characteristics of un-worn CLs of different materials. One material of hydrogel, two of siloxane-hydrogel and one of rigid gas-per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012