Comparison of the Bonfils Intubation Fibrescope versus C-mac Videolaryngoscope.

نویسندگان

  • Ai H Lee
  • Nadia M Nor
  • Azarinah Izaham
  • Nurlia Yahya
  • Shereen S P Tang
  • Norsidah A Manap
چکیده

BACKGROUND This prospective, randomized, single blind, single operator study was conducted to compare hemodynamic responses when endotracheal intubation was performed using the Bonfils intubation fibrescope versus the C-MAC videolaryngoscope. METHOD Forty-four ASA I patients aged between 18 and 60 years, scheduled for elective surgery requiring endotracheal intubation were recruited. They were randomized into the Bonfils group or C-MAC group. Hemodynamic changes, laryngeal view, duration of intubation and post intubation complications were evaluated. Mean arterial pressure, heart rate and oxygen saturation were monitored pre and post-induction, pre and post-intubation, and at 1 minute intervals thereafter for 10 minutes. RESULTS Endotracheal intubation was successful at first attempt in 90.9% in both groups. Heart rate was significantly higher in the Bonfils group (p < 0.05) compared to the C-MAC group and values were sustained throughout the study. There was no difference in the mean arterial pressure (MAP) between the two groups. Mean time to intubation was significantly longer in the Bonfils group (28.8 vs. 24.7 seconds, p = 0.02). There were no significant differences in laryngeal view and post intubation complications between the groups. CONCLUSION Intubation using the Bonfils intubation fibrescope took longer, and resulted in significantly higher heart rate when compared with the C-MAC videolaryngoscope.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intubation success and glottic visualization using King Vision and C-MAC videolaryngoscopes in patients with cervical spine injuries with cervical immobilization: A randomized clinical trial

BACKGROUND Glottic visualization can be difficult with cervical immobilization in patients with cervical spine injury. Indirect laryngoscopes may provide better glottic visualization in these groups of patients. Hence, we compared King Vision videolaryngoscope, C-MAC videolaryngoscope for endotracheal intubation in patients with proven/suspected cervical spine injury. METHODS After standard i...

متن کامل

Current evidence for the use of C-MAC videolaryngoscope in adult airway management: a review of the literature

The C-MAC videolaryngoscope is the first Macintosh-typed videolaryngoscope. Since the advent of its original version video Macintosh system in 1999, this device has been modified several times. A unique feature of C-MAC device is its ability to provide the 2 options of direct and video laryngoscopy with the same device. The available evidence shows that in patients with normal airways, C-MAC vi...

متن کامل

Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways.

BACKGROUND Difficult and failed intubations, although rarely encountered, are major causes of morbidity and mortality in the current anaesthetic practice. To reduce the incidence of difficult and failed intubations, several devices including the recently developed videolaryngoscopes are available. This randomized controlled study aims to compare the use of the McGrath videolaryngoscope with the...

متن کامل

RESPIRATION AND THE AIRWAY Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways

Editor’s key points † The McGrath videolaryngoscope was compared with the C-MAC videolaryngoscope in patients with anticipated difficult airway. † The C-MAC videolaryngoscope allowed a quicker and easier tracheal intubation. † This research adds important data to ongoing comparisons between various newer airway devices. Background. Difficult and failed intubations, although rarely encountered, ...

متن کامل

Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway.

BACKGROUND The Bonfils intubation fibrescope (BIF), a rigid, straight and reusable fibreoptic device, is being used increasingly to facilitate endotracheal intubation after direct laryngoscopy has failed. We tested the hypothesis that, with the BIF compared to direct laryngoscopy, the rate of failed endotracheal intubation could be reduced in patients with a difficult airway, simulated by means...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Middle East journal of anaesthesiology

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 2016