MultiCode-PLx system for multiplexed detection of seventeen respiratory viruses.

نویسندگان

  • Frederick S Nolte
  • David J Marshall
  • Christopher Rasberry
  • Sabina Schievelbein
  • Grier G Banks
  • Gregory A Storch
  • Max Q Arens
  • Richard S Buller
  • James R Prudent
چکیده

The MultiCode-PLx system (EraGen Biosciences, Inc., Madison, WI) for the detection of respiratory viruses uses an expanded genetic alphabet, multiplex PCR chemistry, and microsphere flow cytometry to rapidly detect and specifically identify 17 different respiratory viruses directly in clinical specimens. The MultiCode-PLx system was tested in parallel with direct fluorescent-antibody (DFA) staining and rapid shell vial culture (R-mix cells; Diagnostic Hybrids, Inc. Athens, OH) with 354 respiratory specimens from adult patients that were submitted to the clinical virology laboratory at the Emory University Hospital. Single-target PCRs were performed with retained samples to confirm the positive results obtained with the MultiCode-PLx system for viruses not covered by DFA and R-mix culture (metapneumovirus, coronaviruses [CoV], parainfluenza viruses 4a and 4b, and rhinoviruses) and to resolve any discrepancies between the DFA and R-mix culture and the MultiCode-PLx results for viruses common to both systems. Respiratory viruses were detected in 77 (21.8%) and 116 (32.7%) specimens by DFA and R-mix culture and with the MultiCode-PLx system, respectively. Among the viruses common to both systems, the MultiCode-PLx system detected significantly more influenza A viruses (P = 0.0026). An additional increased diagnostic yield with the MultiCode-PLx system resulted from the detection of human metapneumovirus (HMPV) in 9 specimens, human CoV (HCoV) in 3 specimens, and human rhinovirus (HRV) in 16 specimens. Also, two mixed viral infections were detected by the MultiCode-PLx system (HCoV OC43 and HRV infections and HMPV and HRV infections), but none were detected by DFA and R-mix culture. Single-target PCRs verified the results obtained with the MultiCode-PLx system for 73 of 81 (90.1%) specimens that had discordant results or that were not covered by DFA and R-mix culture. The MultiCode-PLx system provides clinical laboratories with a practical, rapid, and sensitive means for the massively multiplexed molecular detection of common respiratory viruses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a multiplexed PCR assay for detection of respiratory viral pathogens in a public health laboratory setting.

There are numerous viral and bacterial causes of respiratory disease. To enable rapid and sensitive detection of even the most prevalent causes, there is a need for more-simplified testing systems that enable researchers and clinicians to perform multiplexed molecular diagnostics quickly and easily. To this end, a new multiplexed molecular test called the MultiCode-PLx respiratory virus panel (...

متن کامل

High-throughput, sensitive, and accurate multiplex PCR-microsphere flow cytometry system for large-scale comprehensive detection of respiratory viruses.

Human respiratory viruses are a diverse group of pathogens composed of hundreds of virus strains, and this presents a major challenge for diagnostic laboratories. To efficiently detect numerous viruses in a large epidemiologic study, we developed a fast, multitarget, sensitive, and specific assay named the Respiratory MultiCode-PLx Assay (RMA). The RMA utilizes improved multiplex PCR chemistry ...

متن کامل

Comparison of the Eragen Multi-Code Respiratory Virus Panel with conventional viral testing and real-time multiplex PCR assays for detection of respiratory viruses.

High-throughput multiplex assays for respiratory viruses are an important step forward in diagnostic virology. We compared one such assay, the PLx Multi-Code Respiratory Virus Panel (PLx-RVP), manufactured by Eragen Biosciences, Inc. (Madison, WI), with conventional virologic testing, consisting of fluorescent-antibody staining plus testing with the R-mix system and fibroblast tube cultures. Th...

متن کامل

Assessment of liquid microbead arrays for the screening of newborns for spinal muscular atrophy.

BACKGROUND Spinal muscular atrophy is a common neurodegenerative disorder that has recently been considered for inclusion in the next generation of newborn screening regimens. We sought to validate liquid microbead arrays for the identification of affected individuals by direct DNA analysis. METHODS Assays were created to detect the homozygous deletions in exon 7 of the SMN1 gene found in app...

متن کامل

Detection of avian influenza virus of H9 subtype in the feces of experimentally infected chickens by RT–PCR

  Avian Influenza (AI) is a viral respiratory disease of domestic and wild birds. In the diagnostic laboratory, it is essential to have methods for rapid detection of avian respiratory viruses. Cloacal swabs collected from chickens experimentally infected with H9 subtype AI virus, used in a reverse transcription-polymerase chain reaction (RT-PCR) assay for detection of AI. In infected animals, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2007