CT and MR imaging of nitinol stents with radiopaque distal markers.

نویسندگان

  • Laurent Létourneau-Guillon
  • Gilles Soulez
  • Gilles Beaudoin
  • Vincent L Oliva
  • Marie-France Giroux
  • Zhao Qin
  • Nicolas Boussion
  • Eric Therasse
  • Jacques De Guise
  • Guy Cloutier
چکیده

PURPOSE To evaluate imaging characteristics and artifacts of a nitinol stent with distal tantalum markers with computed tomography (CT) angiography and magnetic resonance (MR) angiography. MATERIALS AND METHODS A vascular phantom was built to simulate in-stent restenosis. A nitinol stent with tantalum markers (Luminexx stent) was evaluated with CT angiography in different orientations relative to the z-axis and with MR angiography in different positions relative to both B0 and the readout gradient. Stenosis measurements were compared with conventional digital subtraction angiography for both modalities. In-stent signal intensity obtained with different flip angles was assessed in two nitinol stents with distal markers (Luminexx stent and SMART stent) and one without markers (Memotherm-FLEXX stent). RESULTS Stenosis detection was not possible with CT angiography when the stent was perpendicular to the z-axis because of streak-like artifacts induced by tantalum markers. Stenosis evaluation with multiplanar reformation was accurate when the stent was in parallel and oblique orientations relative to the table axis. With MR angiography, metallic artifacts were mostly related to the stent orientation with B0, whereas orientation of the readout gradient had little influence. The mean error (overestimation) for stenosis measurements varied between 0.1% and 7.4% for CT imaging in parallel and oblique positions and 3.6% and 9.5% for MR imaging. Higher flip angles did not improve signal intensity inside the three stents tested. CONCLUSION CT and MR angiography can be used for evaluating the patency of stents with distal markers that are parallel or oblique relative to the table axis (iliac, carotid, or femoral stents). MR angiography is preferred if the stent is perpendicular to the table axis (renal stent).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils.

BACKGROUND AND PURPOSE Previous studies have depicted arterial and aneurysmal anatomy with three-dimensional time-of-flight (3D-TOF) MR angiography before and after treatment with Guglielmi detachable coils (GDCs) and with CT angiography before and after treatment with stents and stent-grafts. We investigated the ability of time-resolved contrast-enhanced 3D MR angiography (3D MR digital subtra...

متن کامل

Carotid artery stents: in vitro comparison of different stent designs and sizes using CT angiography and contrast-enhanced MR angiography at 1.5T and 3T.

BACKGROUND AND PURPOSE CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. Our aim was to compare CTA, contrast-enhanced MRA (CE-MRA) at 1.5T, and CE-MRA at 3T for the visualization of carotid artery stents and to define the best noninvasive imaging technique as an alternative to conventional angiography for each stent. MATERI...

متن کامل

MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid) stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy) were examined in a vessel phantom (vessel diameters ranging...

متن کامل

Magnetic resonance--guided coronary artery stent placement in a swine model.

BACKGROUND Magnetic resonance (MR)--guided coronary artery stent placement is a challenging vascular intervention because of the small size of the coronary arteries combined with incessant motion during the respiratory and cardiac cycles. These obstacles necessitate higher temporal and higher spatial resolution real-time MR imaging techniques when compared with interventional peripheral MR angi...

متن کامل

Proton radiotherapy dose perturbations caused by esophageal stents of varying material composition are negligible in an experimental model

BACKGROUND Self-expanding metal and plastic esophageal stents (SEMS and SEPS, respectively) are used in conjunction with chemoradiation for palliation of malignant dysphagia. To date, the dosimetric effects of stents undergoing proton radiotherapy are not known. STUDY AIM To investigate the proton radiotherapy dose perturbations caused by esophageal stents of varying designs and materials und...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2004