Administration of ¹³¹I-Metaiodobenzylguanidine Using the Peristaltic Infusion Pump Method.

نویسندگان

  • Miguel de la Guardia
  • Steven McCammon
  • Karen Nielson
  • Meaghan Granger
چکیده

UNLABELLED Syringe pumps are commonly used to administer therapeutic (131)I-metaiodobenzylguanidine. Here we describe our recent experience with a peristaltic infusion pump system in a pediatric setting. This method can easily accommodate infusions from several vials simultaneously and is adaptable to various types of peristaltic pump. METHODS Simple off-the-shelf components are used to vent the vial: a charcoal filter, a 0.22-μm syringe filter, and a 2.54-cm (1-in) needle. The vial is connected to the primary infusion set using a male/male extension line and a 19-gauge × 8.89-cm (3.5-in) aspirating needle. With aseptic technique, the extension line is attached to the Y connector closest to the primary intravenous line leading from the saline reservoir to the infusion pump. An A-clamp is attached to the primary intravenous line, immediately before the entrance to the pump. Gravity is allowed to clear the air from the extension set and the aspirating needle. After all the air has been purged, the aspirating needle is inserted into the therapy vial using aseptic technique. The pump is programmed with the desired infusion rate and volume to be infused. RESULTS Twenty-one consecutive infusions have been performed to date using this method. Most of the infusions involved the use of 1 vial. On 7 occasions, 2 or 3 vials connected in series were used to successfully administer the therapy. Overestimation of the volume in the vials or of the total infusion time required can cause air to be pulled into the lines. To prevent this, the volume in the vials is equalized to 30 mL, facilitating calculation of the infusion time. If the infusion is observed over the last 2 or 3 mL and the pump stops when the air-fluid mark is about halfway up the extension set, air will be kept out of the primary infusion set. CONCLUSION This method for infusing one or more vials of therapeutic radiopharmaceuticals is robust and easy to use. During infusion, the radiopharmaceutical remains in a shielded vial. Multiple vials can be connected in series to infuse the entire dose simultaneously.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Vitro Red Blood Cells Integrity and Morphology Changes after Passing Through Volumetric Peristaltic Infusion Pump

Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...

متن کامل

Performance of a linear peristaltic infusion pump during red blood cells administration and the influence of infusion rates

Introduction Even with the technological development of infusion pumps, pediatric intensive care nurses are resistant to administer red blood cells (RBC) by linear peristaltic infusion pumps due to the supposed risk of cells damage, despite the need of accuracy in low flow rates. Patient safety can be compromised both by RBC quality decrease due to the pumping mechanism, as well as, by possible...

متن کامل

[Evaluation of the pelvi-ureteral function through a new urine bolusmetry. II. Simultaneous measurement of urine bolus volume and electroureterogram].

New equipment to evaluate the urine transport function of the ureteropelvic system has been developed. Simultaneous measurement of urine bolus volume and electrical activity in the ureter is possible by means of this equipment. A urine bolus volume measuring system, which is based on the heat electrical method, is located in the probe tip, and bipolar electrodes for EMG are located in the stem ...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2014