Sources of scattering in cervical tissue: determination of the scattering coefficient by confocal microscopy.
نویسندگان
چکیده
Most models of light propagation through tissue assume that the scattering properties of various tissue layers are the same. We present evidence that the scattering coefficient of cervical epithelium varies by a factor of 3 within the epithelium owing to variations in nuclear density and to the presence of keratin. We estimated the scattering coefficient from regions of normal and precancerous cervical epithelium by fitting reflectance measurements from confocal images to an exponential function of depth based on Beer's law of attenuation. The results suggest that the normal cervix is characterized by highly variable scattering in the superficial epithelium, low scattering in the intermediate epithelium, and high scattering in the basal and stromal regions. In high-grade dysplasia, high scattering from high-density nuclei is observed throughout the entire epithelium.
منابع مشابه
Determination of Epithelial Tissue Scattering Coefficient Using Confocal Microscopy
Most models of light propagation through tissue assume the scattering properties of the various tissue layers are the same. The authors present evidence that the scattering coefficient of normal cervical epithelium is significantly lower than values previously reported for bulk epithelial tissue. They estimated the scattering coefficient of normal and precancerous cervical epithelium using meas...
متن کاملStudy of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملApplication of small angle X-ray scattering (SAXS) for differentiation between normal and cancerous breast tissues
ABSTRACT Background: Coherent scattering leads to diffraction effects and especially constructive interferences. Theseinterferences carry some information about the molecular structure of the tissue. As breast cancer isthe most widespread cancer in women, this project evaluated the application of small angleX-ray scattering (SAXS) for differentiation between normal and cancerous breast tissues....
متن کاملPenetration depth limits of in vivo confocal reflectance imaging.
We present experiments to predict the maximum penetration depth atwhich typical biological structures in amelanotic tissue can bedetected with confocal microscopy. The detected signal is examinedas the signal source strength (index of refraction mismatch), thesource depth, and the medium scattering coefficient are varied. Thedetected background produced by scattering outside the focal volume is...
متن کاملA STUDY OF GAMMA RAY EXPOSURE BUILDUP FACTORS IN STRATIFIED SHIELDS FOR POINT ISOTROPIC SOURCES, INCLUDING THE EFFECTS OF INCOHERENT AND COHERENT SCATTERING
The effects of including incoherent (bound-electron) and coherent (Rayleigh) scattering in exposure buildup factor calculations for point isotropic gamma ray sources, penetrating a two-layer water-lead shield have been investigated in the gamma ray energy (E?) range of 40 keV to 3 MeV. Incoherent scattering decreases the values of these factors in both layers up to E? ~ 200 keV and the effect i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 44 11 شماره
صفحات -
تاریخ انتشار 2005