Thyrotropin as measured by a sensitive immunoradiometric assay.
نویسندگان
چکیده
An immunoradiometric assay (Boots-Celltech's "Sucrosep"; IRMA) for thyrotropin (TSH) was evaluated and results were compared with those of our in-house RIA procedure. The IRMA had a sensitivity of 0.02 milli-int. unit/L. In addition it displayed excellent intra- and inter-batch precision, cross-reacted negligibly with other pituitary hormones, and appeared to be relatively free of matrix effects (although deionized water did give an apparent TSH concentration of 0.13 milli-int. unit/L). Over the range 1.2 to 64 milli-int. units/L, correlation between the IRMA (y) and RIA (x) was excellent: y = 1.16x - 1.69 (r = 0.98). The normal reference interval for the IRMA was 0.4 to 4.2 milli-int. units/L. For patients suspected of hyperthyroidism who had been subjected to the thyroliberin test, the IRMA more effectively differentiated between euthyroidism and hyperthyroidism. During testing with thyroliberin, all nonresponding hyperthyroid patients had initial baseline TSH concentrations of less than 0.02 milli-int. unit/L by IRMA. This sensitive assay represents an important advance in the ability to differentiate between euthyroidism and hyperthyroidism.
منابع مشابه
A sensitive immunoradiometric assay for serum thyroid stimulating hormone.
The value as a thyroid function test of a new, rapid, and highly sensitive immunoradiometric assay for thyroid stimulating hormone (TSH) was assessed in 188 consecutive new patients with suspected hyperthyroidism. The diagnosis was made on clinical grounds and on the basis of serum total triiodothyronine and thyroxine concentrations and the response of TSH to thyrotrophin releasing hormone (TRH...
متن کاملImmunoradiometric assay of thyrotropin as a "first-line" thyroid-function test in the routine laboratory.
We compared the utility of a sensitive immunoradiometric assay for serum thyrotropin as a "first-line" thyroid-function test with a strategy based on first measuring total thyroxin in serum. The immunoradiometric assay appears to distinguish primary hypothyroidism and hyperthyroidism from euthyroidism in "new" patients. The role of this test in monitoring antithyroid treatment or thyroxin-repla...
متن کاملDiagnostic value of thyrotropin concentrations in serum as measured by a sensitive immunoradiometric assay.
A new, highly sensitive immunoradiometric thyrotropin (TSH) assay involving solid-phase-coupled monoclonal antibodies (Boots-Celltech Sucrosep IRMA-TSH) has been evaluated in a wide variety of patients with thyroidal and nonthyroidal illnesses and the results compared with those obtained by conventional diagnostic TSH RIAs. The sensitivity of the present assay ranged from 0.036 to 0.1 milli-int...
متن کاملBernutz, Hörn, König and Pickardt: Sensitive assays for thyrotropin in the diagnosis of thyroid disorders
Using two new immunoradiometric assays for thyrotropin, we measured thyrotropin levels in serum of patients suffering from various clinically and biochemically diagnosed thyroid disorders, and in healthy controls. A thyroliberin Stimulation test was performed in all patients and controls. Thyrotropin levels were measured using a solid phase IRMA in 339 patients and a coated tube sandwich assay ...
متن کاملSerum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.
We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and Thyro-SHure TSH Diagnostic Kit (Nuclear Medical Laboratories). The correlation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 31 11 شماره
صفحات -
تاریخ انتشار 1985