Reliability of hearing thresholds: computer-automated testing with ER-4B Canal Phone earphones.
نویسندگان
چکیده
This study was conducted to document test-retest reliability of hearing thresholds using our computer-automated tinnitus matching technique and Etymotic ER-4B Canal Phone insert earphones. The research design involved repeated threshold measurements both within and between sessions, and testing to evaluate the potential effect of eartip removal and reinsertion. Twenty normal-hearing subjects were evaluated over two testing sessions with the use of a fully automated protocol for determining thresholds with 1-dB precision. Thresholds were first obtained at 0.5-16.0 kHz, in one-third octave frequency steps (16 test frequencies). The octave frequencies were then retested, first without removing the eartips, then after eartip removal and replacement. Responses between sessions differed by an average of 2.5 dB across all 16 test frequencies, and 91.5 percent of the repeated thresholds varied within +/-5 dB (98.1 percent within +/-10 dB). Reliability of within-sessions thresholds was also good, and there was no effect of eartip removal and replacement.
منابع مشابه
Reliability of computer-automated hearing thresholds in cochlear-impaired listeners using ER-4B Canal Phone earphones.
This paper describes the second phase of a study to determine test-retest reliability of hearing thresholds using a computer-automated technique with ER-4B Canal Phone insert earphones. The first phase documented reliable hearing thresholds in 20 normal-hearing individuals. For this second phase, 20 individuals with cochlear hearing loss completed the same testing protocol as for phase one. Dur...
متن کاملHigh-frequency thresholds: circumaural earphone versus insert earphone.
Benefits of high-frequency audiometry in monitoring hearing sensitivity of patients administered ototoxic medications are well established. High-frequency thresholds have been reported to be variable, due in part to small differences in the placement of the earphone diaphragm over the opening of the ear canal. Reliability may be improved by using insert earphones (ER-2) when obtaining high-freq...
متن کاملEvaluation of insert earphones for high-frequency bedside ototoxicity monitoring.
Ototoxic hearing loss is usually detected earliest through monitoring of the highest audible frequencies in individuals administered ototoxic medications. Conducting ototoxicity monitoring may require testing patients in the hospital room. This study evaluated the use of insert earphones for obtaining reliable threshold responses at bedside. Twenty adult subjects were tested during two differen...
متن کاملInfluence of the type of transducer in profound hearing loss.
BACKGROUND individuals with profound hearing loss may present vibrotactile responses when tested with supra-aural earphones due to the large skull area exposed to vibration in these transducers. AIM to verify the influence of the type of transducer when assessing air conducted pure tone thresholds in individuals with profound sensorineural hearing loss. METHOD 50 individuals, ranging in age...
متن کاملReliability and validity of high-frequency (8-20 kHz) thresholds obtained on a computer-based audiometer as compared to a documented laboratory system.
A Macintosh computer-based audiometer (Virtual 320) was evaluated for reliability and validity of high-frequency (8-20 kHz) thresholds by comparison with a well documented laboratory high-frequency evaluation system (PARVA-HF). High-frequency earphones originally provided with the V320 for high-frequency testing required modification to improve reliability in calibration and in subject threshol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of rehabilitation research and development
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2001