Four-corner arthrodesis using two headless compression screws.
نویسندگان
چکیده
We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of motion, pain and complications were collected from the medical files. A total of 77 series of anteroposterior, oblique, and lateral x-rays were reviewed by three independent interpreters ; consensus of at least two was required for the bones to be considered fused. Fusion was achieved in 24/27 wrists. Overall, inter-observer agreement in identifying radiographic bony fusion was fair (κ = 0.41). At the critical timing, 86 (SD 68) days postoperatively, when the decision regarding -fusion was made, inter-observer agreement was poor (κ = 0.07). Our rates of fusion are consistent with -reports in the literature. Radiographs performed at 3 months after four-corner arthrodesis are not -reliable for the diagnosis of fusion.
منابع مشابه
Early motion following 4-corner arthrodesis using cannulated compression screws: a biomechanical study.
PURPOSE To assess the ability of headless compression screws to maintain immobile bony contact throughout wrist cycling following simulated 4-corner arthrodesis. Our hypothesis was that the screw constructs would not permit displacement of the carpal bones and, therefore, could tolerate early postoperative range of motion in vivo. METHODS Using 6 matched-paired cadaveric arms, 4-corner arthro...
متن کاملBiomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.
BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...
متن کاملTreatment of symptomatic distal interphalangeal joint arthritis with percutaneous arthrodesis: a novel technique in select patients.
Arthrodesis of the distal interphalangeal (DIP) joint is a reliable means of achieving pain relief in a symptomatic DIP joint afflicted by a variety of degenerative, inflammatory, or posttraumatic conditions. Successful arthrodesis is more reproducible when rigid compression of the joint is achieved. The emergence of an increasing number of commercially available headless or variable pitch comp...
متن کاملTibiotalocalcaneal arthrodesis with headless compression screws
BACKGROUND Tibiotalocalcaneal arthrodesis with headless compression screws has not been previously reported. We hypothesized that these screws could be suitable for tibiotalocalcaneal arthrodesis because of their special design. This study aimed to evaluate the clinical outcomes of patients undergoing tibiotalocalcaneal arthrodesis with headless compression screws for the treatment of severe ar...
متن کاملResults of Arthroscopic Ankle Arthrodesis with Fixation Using Two Parallel Headless Compression Screws in a Heterogenic Group of Patients
BACKGROUND As orthopedic surgeons become skilled in ankle arthroscopy technique and evidence -based data is supporting its use, arthroscopic ankle arthrodesis (AAA) will likely continue to increase, but stabilization methods have not been described clearly. We present a technique for two parallel 7.3-mm headless compression screws fixation (HCSs) for AAA in cases of ankle arthritis with differe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 82 2 شماره
صفحات -
تاریخ انتشار 2016