Limited value of the cuff-leak test.

نویسنده

  • Steven Deem
چکیده

Stridor following tracheal extubation occurs in approximately 5% of all patients, and approximately 1% of all patients require reintubation for upper-airway obstruction.1 Patients at increased risk for stridor and upper-airway obstruction following extubation include female patients; children,2 particularly those with acute respiratory-tract infections (croup);3 patients who have incurred facial or airway trauma or burns or who have undergone surgery of the head and neck; patients with head and neck malignancies, goiters, or other masses;4 and patients with airway edema due to allergic reactions or massive volume resuscitation. The duration of intubation also plays a role in the likelihood of postextubation stridor, with approximately 7% of patients intubated for longer than 36 hours developing stridor, compared to approximately 1% of those intubated for less than 36 hours.1 The ability to predict which patients will require an escalation of care because of stridor following extubation, possibly culminating in re-intubation, is an obviously desirable goal. Beyond assessment of risk factors, clinicians have long used the so-called “cuff-leak” test to predict postextubation airway patency, wherein the endotracheal tube cuff is deflated and a leak of air around the tube is sought during either spontaneous ventilation (with the endotracheal tube lumen occluded) or positive-pressure ventilation.5 Early reports on the cuff-leak test with intubated children suggested that the presence of an air leak was associated with a low likelihood of clinically important postextubation stridor, whereas the absence of a leak was associated with a high incidence of stridor and re-intubation.2,3 However, later studies with adult patients found that the positive predictive value (true positive tests divided by total positive tests) of the qualitative cuff-leak test was poor; two thirds of patients who did not have a cuff leak did not have clinically important postextubation stridor.4,6 Both of these studies were small, with a total of only 16 patients who did not have a cuff leak. Quantification of the cuff leak by reporting the “leak volume” (inspired minus exhaled tidal volume during positive-pressure ventilation) or the fraction of leak volume (inspired minus exhaled volume divided by inspired tidal volume) has been reported to improve on the original, qualitative test, although, again, in small studies with few patients having no or small cuff leaks.7–9 Furthermore, in the largest study to date that used cuff-leak quantification (n 524, 20 of whom had leak volumes 110 mL) found that the test did not predict postextubation stridor (positive predictive value 0).10 In this issue of RESPIRATORY CARE, Kriner et al add substantially to our understanding of the ability of the cuffleak test to predict postextubation stridor.11 These investigators performed a quantitative cuff-leak test on 462 prospectively identified patients who had been intubated for an average of 5 4 days in medical and surgical intensive care units of a large, urban hospital. Leak volume was determined by measuring the difference in exhaled tidal volume before and after cuff deflation during positive-pressure ventilation, and a failed cuff-leak test was defined as a leak volume of 110 mL, or 15.5% of exhaled volume before cuff deflation, using previously derived thresholds.7,9 As in previous studies, patients with large cuff leaks were unlikely to develop clinically important postextubation stridor (10/380 patients); however, of 82 patients who had cuff leak 110 mL, only 10 developed stridor. The positive predictive value of a failed cuffleak test was thus only 12%—a number that was not appreciably improved by the use of the percentage of exhaled volume to define a failed test (positive predictive value 15%). More tellingly, only 2 of 7 patients who required reintubation had leak volumes 110 mL (positive predictive value for reintubation 2%), and the difference in leak volume between those who did and did not require reintubation was not significantly different (181 158 mL vs 131 137 mL, p 0.47, by my calculations). The authors also identified female gender, increased duration of intubation, and a larger ratio of endotracheal tube to laryngeal size as predictors of stridor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laryngeal Ultrasonography Versus Cuff Leak Test in Predicting Postextubation Stridor

INTRODUCTION Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngea...

متن کامل

Cuff leak volume as a clinical predictor for identifying post-extubation stridor.

BACKGROUND Post-extubation stridor occurs after translaryngeal intubation results to re-intubation in a number of patients. OBJECTIVE To determine the cut-off value of the cuff leak volume test among Thai patients as a predictor for post-extubation stridor MATERIAL AND METHOD Demographic data and cuff leak volume were collected from patients who had been intubated with planned extubation. C...

متن کامل

The cuff leak test: does it "leak" any information?

Post-extubation stridor and upper-airway obstruction are multifactorial in etiology and can occur as a result of laryngotracheal edema, intubation trauma, excessive cuff pressure with mucosal ulceration, and prolonged intubation with secondary inflammation and granuloma formation.1 Cuff leak tests (CLTs) were introduced in an attempt to predict post-extubation upper-airway obstruction and reduc...

متن کامل

The role of the cuff leak test in predicting the effects of corticosteroid treatment on postextubation stridor.

BACKGROUND There is not enough evidence to determine the most appropriate treatment of postextubation stridor. Although the cuff leak test is a simple method to predict postextubation stridor, little is known about its use in monitoring the effects of steroid treatment for this complication. The aim of this study was to evaluate the effect of steroids on postextubation stridor based on the clin...

متن کامل

The cuff-leak test: what are we measuring?

Stridor is one of the most frequent causes of early extubation failure. The cuff-leak test may help to identify patients at risk to develop post-extubation laryngeal edema. However the discrimination power of the cuff-leak test is highly variable and can be use, at best, to detect patients at risk to develop edema but should not be used to postpone extubation as tracheal extubation can still be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2005