Percutaneous transcatheter aortic valve implantation for degenerated surgical bioprostheses: the first case series in Asia with one-year follow-up.
نویسندگان
چکیده
INTRODUCTION Percutaneous transcatheter aortic valve implantation (TAVI) has become an established therapy for inoperable and high-surgical-risk patients with severe aortic stenosis. Although TAVI in patients with degenerated surgical aortic bioprostheses (i.e. valve-in-valve TAVI) is increasingly reported in Western studies, such data is lacking in Asian patients. We describe the initial experience of valve-in-valve TAVI in Asia. METHODS Eight patients who underwent valve-in-valve TAVI due to degenerated aortic bioprostheses were enrolled. The mechanism of bioprosthetic valve failure was stenotic, regurgitation or mixed. All procedures were performed via transfemoral arterial access, using the self-expanding CoreValve prosthesis or balloon-expandable SAPIEN XT prosthesis. RESULTS The mean age of the patients was 71.6 ± 13.2 years and five were male. Mean duration to surgical bioprosthesis degeneration was 10.2 ± 4.1 years. Valve-in-valve TAVI was successfully performed in all patients. CoreValve and SAPIEN XT prostheses were used in six and two patients, respectively. There were no deaths, strokes or permanent pacemaker requirement at 30 days, with one noncardiac mortality at one year. All patients experienced New York Heart Association functional class improvement. Post-procedure mean pressure gradients were 20 ± 11 mmHg and 22 ± 8 mmHg at 30 days and one year, respectively. Residual aortic regurgitation (AR) of more than mild severity occurred in one patient at 30 days. At one year, only one patient had mild residual AR. CONCLUSION In our experience of valve-in-valve TAVI, procedural success was achieved in all patients without adverse events at 30 days. Good clinical and haemodynamic outcomes were sustained at one year.
منابع مشابه
Percutaneous transcatheter aortic valve replacement: first transfemoral implant in Asia.
Surgical aortic valve replacement (AVR) is the standard of care for patients with symptomatic severe aortic stenosis (AS), providing relief of symptoms and prolonging survival. However, many patients are either denied or not offered surgery due to high surgical risk or non-operability for open AVR. The technology of percutaneous aortic valve implantation emerged in 2002, and has since evolved r...
متن کاملTransarterial Medtronic CoreValve system implantation for degenerated surgically implanted aortic prostheses.
BACKGROUND To assess the results of transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve System (MCS), through the transarterial approach, in high-risk patients with degenerated surgically implanted aortic bioprostheses (SP). METHODS AND RESULTS Of 241 patients who underwent TAVI, 10 (4%) had a degenerated SP. The approach was percutaneous transfemoral in 9 cases and s...
متن کاملConcomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.
Transcatheter valve implantation is a novel interventional technique, which was developed as an alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation ...
متن کاملTranscatheter aortic valve implantation: safety and effectiveness of the treatment of degenerated aortic homograft.
INTRODUCTION AND OBJECTIVES Percutaneous aortic valve implantation for patients with severe symptomatic aortic stenosis and a high surgical risk is currently well established. We report our experience in terms of safety and effectiveness of transcatheter aortic valve implantation in other clinical context like the degenerated aortic homografts. METHODS We report our initial experience in four...
متن کاملTranscatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.
OBJECTIVES We report our 8-year experience in transcatheter aortic and mitral valve-in-valve (VinV) implantation. BACKGROUND Feasibility and good early outcomes associated with transcatheter aortic and mitral VinV implantation into failed surgical bioprostheses have been confirmed, but the mid-term and long-term outcomes of transcatheter aortic and mitral VinV is unknown. METHODS A total of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Singapore medical journal
دوره 57 7 شماره
صفحات -
تاریخ انتشار 2016