OBJECTIVE To evaluate whether spinal cord intraoperative monitoring (IOM) with somatosensory and transcranial electrical motor evoked potentials (EPs) predicts adverse surgical outcomes. METHODS A panel of experts reviewed the results of a comprehensive literature search and identified published studies relevant to the clinical question. These studies were classified according to the evidence-based methodology of the American Academy of Neurology. Objective outcomes of postoperative onset of paraparesis, paraplegia, and quadriplegia were used because no randomized or masked studies were available. RESULTS AND RECOMMENDATIONS Four Class I and 8 Class II studies met inclusion criteria for analysis. The 4 Class I studies and 7 of the 8 Class II studies reached significance in showing that paraparesis, paraplegia, and quadriplegia occurred in the IOM patients with EP changes compared with the IOM group without EP changes. All studies were consistent in showing all occurrences of paraparesis, paraplegia, and quadriplegia in the IOM patients with EP changes, with no occurrences of paraparesis, paraplegia, and quadriplegia in patients without EP changes. In the Class I studies, 16%-40% of the IOM patients with EP changes developed postoperative-onset paraparesis, paraplegia, or quadriplegia. IOM is established as effective to predict an increased risk of the adverse outcomes of paraparesis, paraplegia, and quadriplegia in spinal surgery (4 Class I and 7 Class II studies). Surgeons and other members of the operating team should be alerted to the increased risk of severe adverse neurologic outcomes in patients with important IOM changes (Level A).
منابع مشابه
Evidence-based guideline update: Intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials. Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology and the American Clinical Neurophysiology Society.
EVIDENCE-BASED GUIDELINE UPDATE: INTRAOPERATIVE SPINAL MONITORING WITH SOMATOSENSORY AND TRANSCRANIAL ELECTRICAL MOTOR EVOKED POTENTIALS: REPORT OF THE THERAPEUTICS AND TECHNOLOGY ASSESSMENT SUBCOMMITTEE OF THE AMERICAN ACADEMY OF NEUROLOGY AND THE AMERICAN CLINICAL NEUROPHYSIOLOGY SOCIETY John P. Ney, David N. van der Goes, Seattle: Nuwer et al.1 consolidated the best evidence available on the...
متن کاملEvidence-based guideline update: intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials*.
OBJECTIVE To evaluate whether spinal cord intraoperative monitoring (IOM) with somatosensory and transcranial electrical motor evoked potentials (EPs) predict adverse surgical outcomes. METHODS A panel of experts reviewed the results of a comprehensive literature search and identified published studies relevant to the clinical question. These studies were classified according to the evidence-...
متن کاملACNS Guideline: Transcranial Electrical Stimulation Motor Evoked Potential Monitoring.
Motor evoked potentials (MEPs) are electrical signals recorded from neural tissue or muscle after activation of central motor pathways. They complement other clinical neurophysiology techniques, such as somatosensory evoked potentials (SEPs), in the assessment of the nervous system, especially during intraoperative neurophysiologic monitoring (IONM). Somatosensory evoked potentials directly ass...
متن کاملAn approach to intraoperative neurophysiologic monitoring of thoracoabdominal aneurysm surgery.
Thoracoabdominal aneurysm surgery carries an approximate 10% risk of intraoperative paraplegia. Abrupt cord ischemia and the confounding effects of systemic alterations and limb or cerebral ischemia challenges neurophysiologic spinal cord monitoring. This investigation sought a rapid differential monitoring approach to predict or help prevent paraplegia. Thirty-one patients were monitored with ...
متن کاملSpecialty Section on Surgical Neuromonitoring INTRAOPERATIVE MONITORING OF SEGMENTAL SPINAL NERVE ROOT FUNCTION WITH FREE-RUN AND ELECTRICALLY-TRIGGERED ELECTROMYOGRAPHY AND SPINAL CORD FUNCTION WITH REFLEXES AND F-RESPONSES A POSITION STATEMENT BY THE AMERICAN SOCIETY OF NEUROPHYSIOLOGICAL MONITORING
Background Context. Orthodromic ascending somatosensory evoked potentials and antidromic descending neurogenic somatosensory evoked potentials monitor spinal cord sensory function. Transcranial motor stimulation monitors spinal cord motor function but only activates 4–5% of the motor units innervating a muscle. Therefore, 95–96% of the motor spinal cord systems activating the motor units are no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Neurology
دوره 78 8 شماره
صفحات -
تاریخ انتشار 2012