Autocapture compatibility in patients with the MembraneEX lead and Affinity pulse generators.

نویسندگان

  • A Schuchert
  • J Voitk
  • B Liu
  • R Kolk
  • E Stammwitz
  • J Beiras
چکیده

The first Autocapture generation worked well with all recommended leads. The newer Autocapture generation provides a more sensitive resolution for evoked response testing and its implementation in a dual-chamber device. The purpose of the study was to evaluate the performance of the Affinity SR/DR pacemaker with the new Autocapture algorithm in combination with the small surface area pacing lead MembraneEX in 129 patients. Autocapture ventricular threshold, sensing threshold, lead impedance, evoked response (ER) and polarization signals were determined at implantation and discharge, as well as after 1 and 3 months. Autocapture recommendation rate was based on the ER sensitivity test. The median pacing threshold was 0.38, 0.50, 0.75, 0.75 V at implant, discharge, 1 and 3 months post-implant, respectively. The respective data for median lead impedance were 744, 605, 649 and 691 ohms; median sensing threshold was 12.5 mV at all visits. The median ER amplitude was 9.0, 10.1, 9.9 and 10.1 mV and the median polarization signal 0.39 mV at all visits. The frequency of recommended Autocapture activation was 98.3%, 99.2%, 98.3% and 96.2% of all patients at implant, at discharge, 1 and 3 months post-implant respectively. In conclusion, the studied pulse generator enabled, in combination with this pacing lead, in >95% of all patients activation of Autocapture.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compatibility of automatic threshold tracking pacemakers with previously implanted pacing leads in children.

The Autocapture function controls and optimizes the amplitude of the pacing pulse and saves energy. The manufacturer recommends using a special low polarization, low threshold bipolar Pacesetter lead for the Autocapture function. The purpose of this study was to evaluate the compatibility of Autocapture with previously implanted pacing leads. The study included 15 patients (mean age 13.6 +/- 3....

متن کامل

Long-term results of endocardial pacing with Autocapture threshold tracking pacemakers in children.

AIM We aimed to evaluate the long-term results of endocardial pacing with Autocapture threshold tracking pacemakers in children. METHODS AND RESULTS Implantation and follow-up data of 20 children with these pacemakers were retrospectively evaluated. The pacemakers were implanted subpectorally in five and subcutaneously in 15 patients. The indication for pacing was high-grade atrioventricular ...

متن کامل

Initial experience with an autocapture pacemaker system.

INTRODUCTION Autocapture management aims to extend pacemaker longevity without compromising on patient safety by automatically monitoring the pacing threshold and adjusting the pacemaker output for consistent capture. This paper describes our initial experience with the Pacesetter Regency pacemaker with autocapture management. MATERIALS AND METHODS Nineteen patients were implanted with single...

متن کامل

Application of Tabu Search to Optimal Placement of Distributed Generation and Reactive Power Sources

Introducing distributed generation into a power system can lead to numerous benefits including technical, economic, environmental, etc. To attain these benefits, distributed generators with proper rating should be installed at suitable locations. Given the similar effects of distributed generators and capacitor banks on operation indices of a distribution system, simultaneous assignment of best...

متن کامل

Determination of trace amounts of lead by adsorptive cathodic stripping voltammetry in the presence of xylenol orange

Lead forms the complexes with xylenol orange in the basic solution. An adsorptivedifferential pulse stripping method for the determination of lead is proposed. The procedureinvolves an adsorptive accumulation of lead on a hanging mercury drop electrode (HMDE) inthe presence of xylenol orange, followed by reduction of adsorbed lead by voltammetric scanusing differential pulse modulation. The opt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2001