Estimated Average Glucose and Self-Monitored Mean Blood Glucose Are Discordant Estimates of Glycemic Control

نویسندگان

  • James M. Hempe
  • Arlette A. Soros
  • Stuart A. Chalew
چکیده

OBJECTIVE The A1C-Derived Average Glucose study recommended reporting A1C in estimated average glucose (eAG) equivalents. We compared eAG with self-monitored mean blood glucose (MBG) to determine whether eAG is systematically biased due to biological variation in the relationship between MBG and A1C. RESEARCH DESIGN AND METHODS MBG and A1C were recorded from charts of 202 pediatric type 1 diabetic patients at 1,612 clinic visits. Patients were divided into groups with low, moderate, or high A1C bias based on a hemoglobin glycation index (HGI). RESULTS The mean +/- SD values for MBG versus eAG were as follows: total population, 194 +/- 34 vs. 196 +/- 36 mg/dl; low-HGI group, 186 +/- 31 vs. 163 +/- 20 mg/dl; moderate-HGI group, 195 +/- 28 vs. 193 +/- 19 mg/dl; and high-HGI group, 199 +/- 42 vs. 230 +/- 31 mg/dl. CONCLUSIONS eAG underestimated MBG in low HGI patients and overestimated MBG in high HGI patients. Disagreement between eAG and MBG downloaded from patient glucose meters will cause confusion if eAG is implemented for clinical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

eAG bias Estimated average glucose and self-monitored mean blood glucose are discordant estimates of glycemic control Running Title: eAG bias

This is an uncopyedited electronic version of an article accepted for publication in Diabetes Care. The American Diabetes Association, publisher of Diabetes Care, is not responsible for any errors or omissions in this version of the manuscript or any version derived from it by third parties. The definitive publisherauthenticated version will be available in a future issue of Diabetes Care in pr...

متن کامل

Ethnic Differences in Glycemic Markers in Patients With Type 2 Diabetes

OBJECTIVE Recent studies have reported hemoglobin A1c (HbA1c) differences across ethnic groups that could limit its use in clinical practice. The authors of the A1C-Derived Average Glucose study have advocated to report HbA1c in estimated average glucose (AG) equivalents. The aim of this study was to assess the relationships between HbA1c and the mean of three 7-point self-monitored blood gluco...

متن کامل

Evaluating once- and twice-daily self-monitored blood glucose testing strategies for stable insulin-treated patients with type 2 diabetes : the diabetes outcomes in veterans study.

OBJECTIVE To evaluate once- and twice-daily self-monitored blood glucose testing strategies in assessing glycemic control and detecting hypoglycemia or hyperglycemia in patients with stable insulin-treated type 2 diabetes. RESEARCH DESIGN AND METHODS Subjects with stable insulin-treated type 2 diabetes monitored blood glucose four times daily (prebreakfast, prelunch, predinner, and bedtime) f...

متن کامل

Comparison between adherence assessments and blood glucose monitoring measures to predict glycemic control in adults with type 1 diabetes: a cross-sectional study

BACKGROUND Adherence to treatment has been defined as the degree to which a patient's behavior corresponds to medical or health advice; however, the most appropriate method to evaluate adherence to diabetes care has yet to be identified. We conducted analyses to compare adherence assessments and blood glucose monitoring measures with regard to their ability to predict glycemic control in adults...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2010