Giemsa-Stained Wet Mount Based Method for Reticulocyte Quantification: A Viable Alternative in Resource Limited or Malaria Endemic Settings

نویسندگان

  • Wenn-Chyau Lee
  • Bruce Russell
  • Yee-Ling Lau
  • Mun-Yik Fong
  • Cindy Chu
  • Kanlaya Sriprawat
  • Rossarin Suwanarusk
  • Francois Nosten
  • Laurent Renia
چکیده

The quantity of circulating reticulocytes is an important indicator of erythropoietic activity in response to a wide range of haematological pathologies. While most modern laboratories use flow cytometry to quantify reticulocytes, most field laboratories still rely on 'subvital' staining. The specialist 'subvital' stains, New Methylene Blue (NMB) and Brilliant Crésyl Blue are often difficult to procure, toxic, and show inconsistencies between batches. Here we demonstrate the utility of Giemsa's stain (commonly used microbiology and parasitology) in a 'subvital' manner to provide an accurate method to visualize and count reticulocytes in blood samples from normal and malaria-infected individuals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Progress in the Development of Diagnostic Tests for Malaria

The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the ne...

متن کامل

Fluorescence In Situ Hybridization (FISH) Assays for Diagnosing Malaria in Endemic Areas

Malaria is a responsible for approximately 600 thousand deaths worldwide every year. Appropriate and timely treatment of malaria can prevent deaths but is dependent on accurate and rapid diagnosis of the infection. Currently, microscopic examination of the Giemsa stained blood smears is the method of choice for diagnosing malaria. Although it has limited sensitivity and specificity in field con...

متن کامل

Evaluation of "Cyscope", a novel fluorescence-based microscopy technique for the detection of malaria.

INTRODUCTION This study was designed to compare the detection of malaria parasites in peripheral blood smears using the Cyscope malaria rapid fluorescent microscopic technique and light microscopy of Giemsa-stained smears. METHODOLOGY A total of 295 blood smears were collected from patients of all age groups presenting with clinical signs and symptoms of malaria to 10 City Health Clinics in H...

متن کامل

Acridine Orange for malaria diagnosis: its diagnostic performance, its promotion and implementation in Tanzania, and the implications for malaria control.

One hundred years ago, Giemsa's stain was employed for the first time for malaria diagnosis. Giemsa staining continues to be the method of choice in most malarious countries, although, in the recent past, several alternatives have been developed that exhibit some advantages. Considerable progress has been made with fluorescent dyes, particularly with Acridine Orange (AO). The literature on the ...

متن کامل

Laboratory Diagnosis of Malaria

R apid and accurate diagnosis is a key to the success of an effective treatment of malaria. The global impact of malaria has spurred interest in developing diagnostic strategies that will be effective not only in resource-limited areas but also in developed countries, where expertise in malaria diagnosis is often lacking. Accurate diagnosis of malaria is necessary to prevent morbidity and morta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013