Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study.

نویسندگان

  • M Sabaté
  • P W Serruys
  • W J van der Giessen
  • J M Ligthart
  • V L Coen
  • I P Kay
  • A L Gijzel
  • A J Wardeh
  • A den Boer
  • P C Levendag
چکیده

BACKGROUND Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. METHODS AND RESULTS Twenty-one consecutive patients treated with balloon angioplasty and beta-radiation according to the Beta Energy Restenosis Trial-1.5 were included in the study. Volumetric assessment of the irradiated segment and both edges was performed after brachytherapy and at 6-month follow-up. Intravascular ultrasound images were acquired by means of ECG-triggered pullback, and 3-D reconstruction was performed by automated edge detection, allowing the calculation of lumen, plaque, and external elastic membrane (EEM) volumes. In the irradiated segments, mean EEM and plaque volumes increased significantly (451+/-128 to 490.9+/-159 mm(3) and 201.2+/-59 to 241.7+/-74 mm(3); P=0.01 and P=0.001, respectively), whereas luminal volume remained unchanged (250.8+/-91 to 249.2+/-102 mm(3); P=NS). The edges demonstrated an increase in mean plaque volume (26.8+/-12 to 32. 6+/-10 mm(3), P=0.0001) and no net change in mean EEM volume (71. 4+/-24 to 70.9+/-24 mm(3), P=NS), resulting in a decrease in mean luminal volume (44.6+/-16 to 38.3+/-16 mm(3), P=0.01). CONCLUSIONS A different pattern of remodeling is observed in coronary segments treated with beta-radiation after successful balloon angioplasty. In the irradiated segments, the adaptive increase of EEM volume appears to be the major contributor to the luminal volume at follow-up. Conversely, both edges showed an increase in plaque volume without a net change in EEM volume.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between tensile stress and plaque growth after balloon angioplasty treated with and without intracoronary beta-brachytherapy.

AIMS We investigated the influence of tensile stress on plaque growth after balloon angioplasty with and without beta-radiation therapy. METHODS AND RESULTS Thirty-one consecutive patients successfully treated with balloon angioplasty were analysed qualitatively and quantitatively by means of an ECG-gated three-dimensional intravascular ultrasound post-procedure and at follow-up. Eighteen pat...

متن کامل

The relation between de novo atherosclerosis remodeling and angioplasty-induced remodeling in an atherosclerotic Yucatan micropig model.

Geometric remodeling in de novo atherosclerosis and in restenosis after balloon angioplasty constitutes a change in total arterial circumference that, together with plaque growth or neointima formation, determines the lumen of the artery. The heterogeneous nature of arterial obstructions raises the question of whether early and late outcomes (restenosis) of angioplasty are affected by the degre...

متن کامل

Effects of Probucol on Vascular Remodeling After Coronary Angioplasty

Background—We have shown that probucol reduces restenosis after balloon angioplasty. Whether probucol acted via prevention of neointimal formation or improvement in vascular remodeling could not be addressed by angiography and required the use of intravascular ultrasound (IVUS). Methods and Results—Beginning 30 days before angioplasty, 317 patients were randomly assigned to receive probucol, mu...

متن کامل

Effects of intracoronary beta-radiation therapy after coronary angioplasty: an intravascular ultrasound study.

BACKGROUND Endovascular radiation is emerging as a potential solution for the prevention and treatment of restenosis. Its effects on the morphology of unstented vessels cannot be determined by angiography and therefore require the use of intravascular ultrasound. METHODS AND RESULTS Through a 5F noncentered catheter for delivery of a 90Sr/Y source train, 12, 14, or 16 Gy at 2 mm was delivered...

متن کامل

Arterial response during cutting balloon angioplasty: a volumetric intravascular ultrasound study.

BACKGROUND AND PURPOSE Previous studies have demonstrated that the mechanism of acute lumen enlargement after balloon angioplasty is a combination of vessel expansion and plaque redistribution, but not plaque compression. The purpose of this study was to clarify, from a three-dimensional aspect, the vascular response to cutting balloon angioplasty. METHODS Serial intravascular ultrasound (IVU...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 100 11  شماره 

صفحات  -

تاریخ انتشار 1999