Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT.

نویسندگان

  • Marcel N Menke
  • Pascal Knecht
  • Veit Sturm
  • Simeon Dabov
  • Jens Funk
چکیده

PURPOSE Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility of 3D-OCT RNFL thickness measurements in healthy volunteers. METHODS Thirty-eight eyes were included in the study. High-density 6-mm(2) 3D scans were registered by two independent operators. RNFL thickness was calculated for eight areas corresponding to the ETDRS areas and for two ring areas. The ETDRS grid was centered on the optic disc. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Interobserver reproducibility was visualized by using Bland-Altman analysis. RESULTS Intrasession reproducibility was good with a mean ICC of 0.90. The mean COV for operator 1 and 2 was 4.2% and 4%, respectively (range, 1.9%-6.7%). Highest reproducibility was found for the two ring areas and the superior and inferior quadrants. Mean differences in RNFL thickness measurements for ring 1 and 2 between operator 1 and 2 were 0.9 microm (limits of agreement, -11.4 to +9.6 microm) and 0.1 microm (limits of agreement -4.1 to +3.9 microm), respectively. CONCLUSIONS 3D-OCT RNFL thickness measurements in healthy volunteers showed good intra- and interobserver reproducibility. 3D-OCT provides more RNFL thickness information compared to conventional time-domain OCT measurements and may be useful for the management of glaucoma and other optic neuropathies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Retinal Nerve Fiber Layer Thickness Measurements in Healthy Subjects Using Fourier and Time Domain Optical Coherence Tomography

Purpose. To compare the retinal nerve fiber layer (RNFL) measurements using two different ocular coherence tomography (OCT) devices: Cirrus Fourier domain OCT and Stratus time domain OCT. To analyze reproducibility of Fourier domain measurements in healthy subjects. Methods. One hundred and thirty-two eyes of 132 healthy subjects were scaned on the same day with both instruments, separated by 1...

متن کامل

Fourier-domain OCT in multiple sclerosis patients: reproducibility and ability to detect retinal nerve fiber layer atrophy.

PURPOSE To evaluate the ability of Fourier-domain (FD) optical coherence tomography (OCT) to detect retinal nerve fiber layer (RNFL) atrophy in multiple sclerosis (MS) patients. To test the intrasession reproducibility of RNFL thickness measurements in MS and healthy subjects using Cirrus (Carl Zeiss Meditec, Dublin, CA) and Spectralis (Heidelberg Engineering, Heidelberg, Germany) OCT. METHOD...

متن کامل

Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.

PURPOSE To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain ...

متن کامل

Reproducibility of retinal nerve fiber layer thickness measurements using spectral domain optical coherence tomography.

PURPOSE To evaluate the reproducibility of the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained by Spectralis spectral domain optical coherence tomography (OCT) (Heidelberg Engineering, Heidelberg, Germany) in normal and glaucoma participants. METHODS Participants were recruited from a university-based clinic. Peripapillary RNFL thickness measurements were repeat...

متن کامل

Retinal nerve fiber layer analysis in RP patients using Fourier-domain OCT.

PURPOSE To determine peripapillary retinal nerve fiber layer thickness (RNFL) abnormalities in patients with retinitis pigmentosa (RP) using Fourier-domain optical coherence tomography (Fd-OCT) and to evaluate the potential effect of cystoid macular edema (CME) or axial length on RNFL measurements in such patients. METHODS Ninety-seven eyes of 52 patients with diagnoses of retinitis pigmentos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 49 12  شماره 

صفحات  -

تاریخ انتشار 2008