Myocardial clearance of technetium-99m-teboroxime in reperfused injured canine myocardium

نویسندگان

  • David R Okada
  • Gerald Johnson
  • Robert D Okada
چکیده

BACKGROUND Recent technical developments using solid-state technology have enabled rapid image acquisition with single photon emission computed tomography (SPECT) and have led to a renewed interest in technetium-99m-teboroxime (Tc-99m-teboroxime) as a myocardial imaging agent. Tc-99m-teboroxime has demonstrated high myocardial extraction, linear myocardial uptake relative to flow even at high flow rates, rapid uptake and clearance kinetics, and differential clearance in the setting of ischemia. However, the myocardial clearance kinetics of Tc-99m-teboroxime in a model of myocardial injury has not been previously reported. Thus, the purposes of this study were to use a canine model of ischemia-reperfusion to (1) compare Tc-99m-teboroxime clearance kinetics in normal and ischemic-reperfused myocardium and (2) assess the utility of Tc-99m-teboroxime clearance kinetics in determining the severity of injury following ischemia-reperfusion. METHODS Thirteen dogs underwent left circumflex coronary artery (LCx) occlusion for either 30 min (IR30, n = 6) or 120 min (IR120, n = 7), followed by reperfusion, and finally Tc-99m-teboroxime administration 120 min after reperfusion. Microsphere blood flows were determined at baseline, during occlusion, after reperfusion, and before euthanasia. Post-mortem, area at risk was determined using Evans blue dye, and viability was determined using triphenytetrazolium chloride (TTC) staining. The hearts were then subdivided into 24 pieces and Tc-99m activity was measured in a well counter. RESULTS TTC-determined infarct area as a percentage of total left ventricular myocardium was 1.1% ± 0.3% for the IR30 group and 7.5% ± 2.9% for the IR120 group (p < 0.05). During coronary occlusion, both the IR30 and IR120 groups demonstrated decreases in percent wall thickening in the ischemia-reperfusion zone (IRZ) as compared with the normal zone (NZ). In the IR30 group, percent wall thickening in the IRZ recovered during the reperfusion phase as compared with the NZ. In the IR120 group, percent wall thickening in the IRZ remained depressed during the reperfusion phase and through the end of the experiment as compared with the NZ. Final Tc-99m-teboroxime myocardial IRZ/NZ activity ratio was 0.94 ± 0.01 for the IR30 group, compared to 0.80 ± 0.01 for the IR120 group (p < 0.05). CONCLUSIONS Tc-99m-teboroxime demonstrates moderate differential clearance in a model of severe injury with 120 min of ischemia-reperfusion, but only minimal differential clearance in a model of mild injury with 30 min of ischemia-reperfusion. Thus, Tc-99m-teboroxime clearance kinetics may be helpful in differentiating normal and minimally injured from severely injured myocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of technetium-99m teboroxime tomography with automated quantitative coronary arteriography and thallium-201 tomographic imaging.

Technetium-99m (Tc-99m) teboroxime is a new perfusion tracer that is highly extracted and rapidly cleared by the myocardium. To determine the feasibility of Tc-99m teboroxime imaging in the diagnosis of patients with suspected coronary artery disease, 30 patients underwent single photon emission computed tomography imaging with Tc-99m teboroxime (25.2 +/- 1 mCi) at peak exercise and again 60 mi...

متن کامل

Effect of methylprednisolone upon technetium-99m pyrophosphate assessment myocardial necrosis in the canine countershock model.

Repeat DC countershock reproducibly results in myocardial necrosis in dogs. In this model, myocardial technetium-99m pyrophosphate (PYP) uptake correlates linearly with tissue creatine kinase depletion (r = -0.83). The effect of pretreatment with methylprednisolone (MP) was studied with PYP in 25 dogs. In myocardium damaged by countershock, 12 MP dogs had higher tissue radioactivity sample:norm...

متن کامل

Myocardial kinetics of Tc-MIBI in canine myocardium after dipyridamole.

Technetium 99m-hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) is a promising new myocardial perfusion imaging agent producing excellent rest images. Imaging, however, will need to be performed with exercise or dipyridamole to detect ischemia and to differentiate salvaged but still ischemic myocardium from scar. Accordingly, 12 dogs were given mild-to-moderate left circumflex coronary ste...

متن کامل

Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: preliminary results.

Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patien...

متن کامل

Effect of Methylprednisolone upon Technetium-99m Pyrophosphate Assessment of Myocardial Necrosis in the Canine Countershock Model

Repeat DC countershock reproducibly results in myocardial necrosis in dogs. In this model, myocardial technetium99m pyrophosphate (PYP) uptake correlates linearly with tissue creatine kinase depletion (r = -0.83). The effect of pretreatment with methylprednisolone (MP) was studied with PYP in 25 dogs. In myocardium damaged by countershock, 12 MP dogs had higher tissue radioactivity sample:norma...