Micellar Liquid Chromatographic Determination of Aluminum Using 8-hydroxyquinoline-5-sulphonic Acid

نویسندگان

  • N. Memon
  • M. I. Bhanger
چکیده

A micellar liquid-chromatographic method is proposed for determination of Al(III) as the 8-hydroxyquinoline-5-sulfonic acid derivative, with spectrofluorimetric detection. Cetyltrimethylammonium bromide, a cationic surfactant (0.05 M), was used as mobile phase. The metal chelate was detected at λEx 410 and λEm 510 nm. Response to aluminum is selective in the presence of other metal ions. The method eliminates the need for addition of reagent or organic modifier to the mobile phase, as is normal in RP HPLC. Under optimized conditions the linear range was 20–200 μg L Al(III), the limit of detection 10 μg L, and the limit of quantification 40 μg L. The method was used to determine aluminum in a variety of water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect determination of trace amounts of fluoride in natural waters by ion chromatography: a comparison of on-line post-column fluorimetry and ICP-MS detectors.

An alternative method for the determination of trace levels of fluoride in drinking and sea-water samples is presented. It is based on the formation of the aluminium monofluoride complex in excess of Al3+ and separation of the two species formed (AlF2+ and Al3+) in a small (5 cm long, CG2) ion exchange guard column. The final determination is accomplished by both ICP-MS specific detection and p...

متن کامل

Spectrophotometric Determination of Tantalum(V) with 5-Iodo-8- -hydroxyquinoline-7-sulphonic Acid

Tantalum(V) reacts with 5-iodo-8-hydroxyquinoline-7-sulphonic acid to form a yellowish coloured complex having maximum absorbance at 405 nm in citric acid medium. The relatively slow reaction at room temperature is completed in 10 minutes at 40 °c. The colour is stable for at least 12 hr. Effects of heating temperature, time, pH, reagent concentration and other variables have been studied. The ...

متن کامل

Development and validation of a stability-indicating micellar liquid chromatographic method for the determination of timolol maleate in the presence of its degradation products.

A stability-indicating micellar liquid chromatographic (MLC) method was developed and validated for the quantitative determination of timolol maleate (TM) in the presence of its degradation products resulting from accelerated degradation in a run time not more than 8 min. TM was subjected to stress conditions of hydrolysis (including alkaline, acidic and thermal hydrolysis) and oxidation. An is...

متن کامل

Micellar Aided Chromogenic Reagents for Simultaneous Spectrophotometric Determination of Aluminium and Iron

Simple and novel spectrophotometric method is described for simultaneous determination of aluminium and iron. The method is based on the metal ions complexes formed by aluminium and iron with mixed chromogenic reagents of 1, 10 phenanthroline and 8-hydroxyquinoline (oxine). The derivatives have absorption maxima at 400 nm and 510 nm respectively in the presence of cetyltrimethyl ammonium bromid...

متن کامل

Rapid determination of acetaminophen in physiological fluids by liquid chromatography using SDS mobile phase and ED detection.

Acetaminophen is determined in serum and urine samples by a rapid, sensitive, and precise chromatographic method without any pretreatment step in a C18 column using a pure micellar mobile phase of 0.02M sodium dodecyl sulfate at pH 7. Acetaminophen is eluted in less than 5 min with no interference of the protein band. The use of electrochemical and UV detection is compared. Linearities (r > 0.9...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004