Measurement of retinal blood vessel width using computerized image analysis.

نویسندگان

  • A M Eaton
  • D L Hatchell
چکیده

We report a new method for quantitating retinal blood vessel width from fluorescein angiogram negatives using a computerized image analyser. Interuser and intrauser variability were 3 to 4 times lower than reported with older methods. In addition, model blood vessels were used to test the accuracy of our method under four clinically relevant conditions: variations in vessel width, fluorescein concentration, flash intensity and background fluorescence. Although computed measurements were affected by vessel width, fluorescein concentration and flash intensity, the linearity of the actual versus computed width was maintained during wide variations in all four conditions (r = 0.95, P less than 0.0001). Accuracy was best achieved at a flash intensity of 150 W/sec and a fluorescein concentration of 45 micrograms/ml. The results of this study provide a better understanding of factors affecting the apparent width of retinal blood vessels in fluorescein angiograms. This technique should be useful in rapidly obtaining accurate measurements of blood vessel width from fluorescein angiograms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracting Vessel Centerlines From Retinal Images Using Topographical Properties and Directional Filters

In this paper we consider the problem of blood vessel segmentation in retinal images. After enhancing the retinal image we use green channel of images for segmentation as it provides better discrimination between vessels and background. We consider the negative of retinal green channel image as a topographical surface and extract ridge points on this surface. The points with this property are l...

متن کامل

Vessel Cross-Sectional Diameter Measurement on Color Retinal Image

Vessel cross-sectional diameter is an important feature for analyzing retinal vascular changes. In automated retinal image analysis, the measurement of vascular width is a complex process as most of the vessels are few pixels wide or suffering from lack of contrast. In this paper, we propose a new method to measure the retinal blood vessel diameter which can be used to detect arteriolar narrowi...

متن کامل

Automated delineation and quantitative analysis of blood vessels in retinal fundus image

Automated fundus image analysis plays an important role in the computer aided diagnosis of ophthalmologic disorders. A lot of eye disorders, as well as cardiovascular disorders, are known to be related with retinal vasculature changes. Many studies has been done to explore these relationships. However, most of the studies are based on limited data obtained using manual or semi-automated methods...

متن کامل

Computerized analysis of retinal vessel width and tortuosity in premature infants.

PURPOSE To determine, with novel software, the feasibility of measuring the tortuosity and width of retinal veins and arteries from digital retinal images of infants at risk of retinopathy of prematurity (ROP). METHODS The Computer-Aided Image Analysis of the Retina (CAIAR) program was developed to enable semiautomatic detection of retinal vasculature and measurement of vessel tortuosity and ...

متن کامل

Blood vessel diameter Measurement on retinal Image

Accurate measurement of vessel diameters on retinal images plays an important part in diagnosing cardiovascular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. In this study we develop new method based on computer aided to determine the width of retinal blood vessels by analysing the color fundus image. Retinal vessel diameter was measured based on bloo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 29 8  شماره 

صفحات  -

تاریخ انتشار 1988