TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions.

نویسندگان

  • Eberhard Grube
  • Sigmund Silber
  • Karl Eugen Hauptmann
  • Ralf Mueller
  • Lutz Buellesfeld
  • Ulrich Gerckens
  • Mary E Russell
چکیده

BACKGROUND The TAXUS NIRx stent (Boston Scientific Corp) provides local delivery of paclitaxel via a slow-release polymer coating. The TAXUS I trial was the first in-human experience evaluating safety and feasibility of the TAXUS NIRx stent system compared with bare NIR stents (control) (Boston Scientific Corp) for treatment of coronary lesions. METHODS AND RESULTS METHODS AND RESULTS The TAXUS I trial was a prospective, double-blind, three-center study randomizing 61 patients with de novo or restenotic lesions (< or =12 mm) to receive a TAXUS (n=31) versus control (n=30) stent (diameter 3.0 or 3.5 mm). Demographics, lesion characteristics, clinical outcomes were comparable between the groups. The 30-day major adverse cardiac event (MACE) rate was 0% in both groups (P=NS). No stent thromboses were reported at 1, 6, 9, or 12 months. At 12 months, the MACE rate was 3% (1 event) in the TAXUS group and 10% (4 events in 3 patients) in the control group (P=NS). Six-month angiographic restenosis rates were 0% for TAXUS versus 10% for control (P=NS) patients. There were significant improvements in minimal lumen diameter (2.60+/-0.49 versus 2.19+/-0.65 mm), diameter stenosis (13.56+/-11.77 versus 27.23+/-16.69), and late lumen loss (0.36+/-0.48 versus 0.71+/-0.48 mm) in the TAXUS group (all P<0.01). No evidence of edge restenosis was seen in either group. Intravascular ultrasound analysis showed significant improvements in normalized neointimal hyperplasia in the TAXUS (14.8 mm3) group compared with the control group (21.6 mm3) (P<0.05). CONCLUSIONS In this feasibility trial, the TAXUS slow-release stent was well tolerated and showed promise for treatment of coronary lesions, with significant reductions in angiographic and intravascular ultrasound measures of restenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions.

BACKGROUND Early clinical studies demonstrated the feasibility of local paclitaxel delivery in reducing restenosis after treatment of de novo coronary lesions in small patient populations. METHODS AND RESULTS We conducted a randomized, double-blind trial of 536 patients at 38 medical centers evaluating slow-release (SR) and moderate-release (MR) formulations of a polymer-based paclitaxel-elut...

متن کامل

One-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent

Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...

متن کامل

One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent in patients with diabetes mellitus.

Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...

متن کامل

Final 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions.

BACKGROUND The TAXUS II trial was designed to evaluate the safety and efficacy of the commercialized slow-release (SR) and an investigation-only moderate-release (MR) polymer-based TAXUS paclitaxel-eluting stent compared with a bare-metal stent for the treatment of de novo coronary lesions. METHODS AND RESULTS This prospective, randomized, double-blind, controlled trial enrolled 536 patients ...

متن کامل

One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial.

BACKGROUND The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. METHODS AND RESULTS In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 107 1  شماره 

صفحات  -

تاریخ انتشار 2003