Three-dimensional echocardiography. In vivo validation for left ventricular volume and function.

نویسندگان

  • S C Siu
  • J M Rivera
  • J L Guerrero
  • M D Handschumacher
  • J P Lethor
  • A E Weyman
  • R A Levine
  • M H Picard
چکیده

BACKGROUND Current two-dimensional quantitative echocardiographic methods of volume assessment require image acquisition from standardized scanning planes. Left ventricular volume and ejection fraction are then calculated by assuming ventricular symmetry and geometry. These assumptions may not be valid in distorted ventricles. Three-dimensional echocardiography can quantify left ventricular volume without the limitations imposed by the assumptions of two-dimensional methods. We have developed a three-dimensional system that automatically integrates two-dimensional echocardiographic images and their positions in real time and calculates left ventricular volume directly from traced endocardial contours without geometric assumptions. METHODS AND RESULTS To study the accuracy of this method in quantifying left ventricular volume and performance in vivo, a canine model was developed in which instantaneous left ventricular volume can be measured directly with an intracavitary balloon connected to an external column. Ten dogs were studied at 84 different cavity volumes (4 to 85 cm3) and in conditions of altered left ventricular shape produced by either coronary occlusion or right ventricular volume overload. To demonstrate clinical feasibility, 19 adult human subjects were then studied by this method for quantification of stroke volume. Left ventricular volume, stroke volume, and ejection fraction calculated by three-dimensional echocardiography correlated well with directly measured values (r = .98, .96, .96 for volume, stroke volume, and ejection fraction, respectively) and agreed closely with them (mean difference, -0.78 cm3, -0.60 cm3, -0.32%). In humans, there was a good correlation (r = .94, SEE = 4.29 cm3) and agreement (mean difference, -0.98 +/- 4.2 cm3) between three-dimensional echocardiography and Doppler-derived stroke volumes. CONCLUSIONS Three-dimensional echocardiography allows accurate assessment of left ventricular volume and systolic function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی

Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...

متن کامل

Fetal ventricular mass determination on three-dimensional echocardiography: studies in normal fetuses and validation experiments.

BACKGROUND Estimation of ventricular volume and mass is important for baseline and serial evaluation of fetuses with normal or abnormal hearts. Direct measurement of chamber wall volumes and mass can be made without geometric assumptions by 3D fetal echocardiography. Our goals were to determine the feasibility of using fast nongated 3D echocardiography for fetal volumetric and mass assessments,...

متن کامل

Three-dimensional echocardiography. In vivo validation for right ventricular volume and function.

BACKGROUND Current two-dimensional echocardiographic measures of right ventricular volume are limited by the asymmetrical and crescentic shape of the ventricle and by difficulty in obtaining standardized views. Three-dimensional echocardiographic reconstruction, which does not require geometric assumptions or standardized views, may therefore have potential advantages for determining right vent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 88 4 Pt 1  شماره 

صفحات  -