Ventilation Design in Animal Research Facilities Using Static Microisolators
نویسنده
چکیده
This paper presents the key conclusions from an extensive research project on ventilation design in animal research facilities using static microisolators. This study, which is presented in full in Memarzadeh (1998), considered both experimental and numerical aspects using the computational fluid dynamics (CFD) technique. As well as a summary of various gaseous generation rates for mice, this paper contains conclusions on the effects of changing various parameters within an animal research room on conditions in the cages and in the main room volume itself. These parameters include, but are not limited to, supply type, exhaust location and number, room ventilation rate, and supply air temperature and moisture content.
منابع مشابه
Control of Ammonia Production in Animal Research Facilities Through Ventilation System Design
This paper considers the effect of air properties on ammonia levels in the cages and main room space of an animal research facility containing mouse static microisolators. The ammonia production from mice is affected by the level of relative humidity (RH) of the air, with higher production rates at elevated RH values. The manipulation of the room supply discharge air, therefore, offers a means ...
متن کاملEngineering control of airborne disease transmission in animal laboratories.
We here present a review of the problem of controlling airborne disease transmission in animal research facilities, with emphasis on engineering design and air-treatment technologies. Dilution ventilation, pressurization control, source control, and air disinfection and removal systems are reviewed, and analytical studies on the effects of dilution ventilation, filtration, and ultraviolet germi...
متن کاملDevelopment of a visual Basic 6.0 based smart application for the design and selection of local exhaust ventilation systems
Introduction: Air pollution in industrial work environments has adverse effects on worker health, for example, chronic obstructive pulmonary disease and asthma. These diseases impose direct and indirect costs on society. In hierarchy controls, local exhaust ventilation is considered an "engineering control" to remove or control contaminants released in indoor work environments. It is one of the...
متن کاملModal Analysis Turboshaft Test Stand Motor Designed by Using ANSYS
Today, modeling is critical for cognition and analysis of designers in industry field to meet their needs and design based on design requirements and available facilities to accelerate production and development of components of industrial engines. In this study, one structure has been proposed, designed, and analyzed based on turboshaft marine engine type to test this kind of engine in order t...
متن کاملAdvances in cubicle design using computational fluid dynamics as a design tool.
As part of a recent animal facility refurbishment, a cubicle containment system was designed to increase the amount of experimental space and also provide containment facilities to support the holding and use of specialized animal models. In order to achieve this, a series of computational fluid dynamic (CFD) studies was undertaken to evaluate the effects of different airflows and in order to o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -