Graphene-modified interdigitated array electrode: fabrication, characterization, and electrochemical immunoassay application.
نویسندگان
چکیده
We have developed a new procedure for fabricating interdigitated array gold electrodes (Au-IDA) modified with reduced graphene oxide (rGO). In this procedure, we coated the gold surface of the micrometer order electrodes with graphene oxide (GO) prior to the reduction and the lift-off processes to avoid short-circuiting the pair of electrodes by conductive rGO flakes after the reduction. We then studied the basic electrochemical activity of the prepared electrodes, rGO/Au-IDA, mainly on p-aminophenol (pAP), because pAP is a good probe for an electrochemical immunoassay. The voltammograms showed that denser rGO provides better electrode reactivity for pAP. We confirmed that redox cycling between the anode and cathode at the rGO/Au-IDA was established, which yields more sensitive detection than with a single electrode. As one application of the electrochemical immunoassay using the rGO/Au-IDA, we demonstrated the quantitative detection of cortisol, a stress marker, at levels found in human saliva.
منابع مشابه
FABRICATION AND CHARACTERIZATION OF POLYANILINE-GRAPHENE COMPOSITE AS ELECTRODE IN ELECTROCHEMICAL CAPACITOR
In this study, polyaniline-graphene composites with different nano-structures are synthesized and the behaviour of the obtained composites serving as electrode materials in electrochemical capacitors is studied. The morphology, crystal structure, and thermal stability of the composites are examined using scanning electron microscopy (SEM), X-ray diffraction (XRD), and Thermal gravimetric analys...
متن کاملFabrication of Graphene–LaMnO3 Sensor for Simultaneous Electrochemical Determination of Dopamine and Uric Acid
Dopamine (DA) and uric acid (UA) are two of important bimolecular widely circulated in body blood. Therefore, development of simple and rapid methods for simultaneous determination of them in routine analysis has a great significance for many researchers. Therefore, for the first time, nanocomposite of graphene (Gr)LaMnO3has been utilized to fabricate the new ...
متن کاملDetermination of epinephrine in the presence of uric acid and folic acid using nanostructure-based electrochemical sensor
Fabrication and electrochemical characterization of a sensor for the determination of epinephrine (EP), uric acid (UA) and folic acid (FA) is described. The sensor was prepared using carbon paste electrode (CPE) modified with 3,4-dihydroxybenzaldehyde-2,4-dinitrophenylhydrazone (DDP) and carbon nanotubes (CNTs), which makes the modified electrode highly sensitive for the electrochemical detect...
متن کاملSensitive Electrochemical Determination of Gallic Acid: Application in Estimation of Total Polyphenols in Plant Samples
A modified electrode was prepared by modification of the carbon paste electrode (CPE) with graphene nano-sheets. The fabricated modified electrode exhibited an electrocatalytic activity toward gallic acid (GA) oxidation because of good conductivity, low electron transfer resistance and catalytic effect. The graphene modified CPE had a lower overvoltage and enhanced electrical current respect to...
متن کاملDesign and Fabrication of Biosensor Based on Immobilized AchE on Modified Electrode by Graphene-multiwall Carbon Nanotubs/Beta Cyclodexterin-chitosan
Organophosphorus (OP) forms an important class of toxic compounds. They inhibit acetyl cholinesterase (AChE, EC 3.1.1.7) that results in respiratory and myocardial malfunctions. Pesticides could be accumulated in vegetables and fruits, so detection of them is very important. The goals of this study are decreasing detection time and detection limit of methyl parathion bioprobe. In this research ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 29 1 شماره
صفحات -
تاریخ انتشار 2013