Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model.
نویسندگان
چکیده
BACKGROUND AND PURPOSE In carotid artery stent placement, marked oversizing of the stent relative to the internal carotid artery lumen is common. This study was performed to determine the influence of using oversized self-expanding nitinol stents on neointimal hyperplasia. METHODS In six greyhound dogs, 24 self-expanding nitinol stents (eight SMART stents, eight Easy Wallstents, eight Sinus-Flex stents) were inserted into both common carotid arteries (CCAs). In each CCA, two stents were deployed; a stent of the appropriate diameter was implanted distally and an oversized stent proximally. After 4 months, transverse sections of each stent were examined histologically and at computerized image analysis. Neointimal hyperplasia was determined as the proportion of the residual diameter of the patent vessel lumen compared with the stent lumen. RESULTS The amount of neointimal hyperplasia did not differ between the normal-sized and oversized stents. The mean preserved luminal diameter (+/-SEM) with normal- and oversized stents, respectively, were as follows: Easy Wallstent, 94% +/- 1.0 and 96% +/- 1.5; SMART stent, 92% +/- 1.6 and 93% +/- 1.8; and Sinus-Flex stent, 93% +/- 2.7 and 93% +/- 2.6. The mean preserved patent lumen with the 12 normal-sized stents (93% +/-1.0) was not significantly different from that of the 12 oversized stents (94% +/- 1.1, P =.502). CONCLUSION Under experimental conditions, use of self-expanding stents oversized by 30-40% appeared to result in neointimal hyperplasia comparable to that caused by normal-sized stents. All three stent types appeared to have similarly low neointimal responses.
منابع مشابه
Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model.
OBJECTIVE Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent c...
متن کاملSelf-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.
PURPOSE To assess the efficacy of metal stents for the treatment of different forms and sizes of carotid aneurysms. METHODS A total of 14 experimentally constructed aneurysms in dogs were treated with transfemorally placed balloon-expandable tantalum and self-expanding nitinol stents. RESULTS In 10 cases, stenting produced either immediate complete occlusion of the aneurysm (n = 7) or compl...
متن کاملMechanisms and predictors of carotid artery stent restenosis: a serial intravascular ultrasound study.
OBJECTIVES The aim of this study was to determine the mechanisms and predictors of carotid artery restenosis after carotid artery stenting (CAS) using serial intravascular ultrasound (IVUS) imaging. BACKGROUND Carotid artery stenting is increasingly used to treat high-grade obstructive carotid disease, but our knowledge of carotid in-stent restenosis and remodeling remains limited. METHODS ...
متن کاملCarotid stenting using heparin-coated balloon-expandable stent reduces intimal hyperplasia in a baboon model.
PURPOSE This study evaluates the effect of heparin-coated balloon-expandable stents on intimal hyperplasia following carotid artery stenting in a baboon model. MATERIALS AND METHODS Balloon-expandable (Palmaz-Schatz) stents were placed in bilateral common carotid arteries in 26 male baboons (mean weight: 11.3 kg). In each animal, a heparin-coated (HC) carotid stent was placed on one side, whe...
متن کاملSafety and biocompatibility of a novel self-expanding nitinol carotid stent with hybrid cell design in a porcine model of neointimal hyperplasia.
BACKGROUND Stent design may influence the outcomes, suggesting that adverse event rates vary according to free cell area and cell design. Open cell design technology of self-expandable stents, dedicated for carotid revascularisation has better deliverability, although closed cell technology is expected to cause fewer thromboembolic events. AIM To evaluate the feasibility and vascular response...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 23 1 شماره
صفحات -
تاریخ انتشار 2002