Doppler-Catheter Gradient Relation for Bileaflet Aortic Valve Prostheses
نویسنده
چکیده
Background. Considerable discrepancies between Doppler and catheter gradients caused by localized gradients and pressure recovery have been reported for normal bileaflet aortic valve prostheses. Methods and Results. To examine whether this Doppler-catheter gradient relation is affected by prosthetic valve malfunction, a 19-mm CarboMedics aortic valve was simultaneously studied with continuous-wave Doppler and catheter technique in normal function and in various states of malfunction ranging from slightly restricted opening to total occlusion of one leaflet. For each functional status, peak and mean gradients were measured at eight different flow rates (cardiac output, 2.0-6.0 L/min). Excellent correlation between Doppler and catheter gradients was found regardless of the valve function (r=0.99, SEE= 1.0-3.3 mm Hg). However, the relation between Doppler and catheter gradient was highly dependent on the function of the valve as shown by a variation of slopes from 1.08 to 2.08. For the normally functioning valve (angle between flow axis and leaflet 50), peak and mean Doppler gradients were approximately twice the catheter gradients (slope, 2.08 and 2.03 for peak and
منابع مشابه
Effect of prosthetic valve malfunction on the Doppler-catheter gradient relation for bileaflet aortic valve prostheses.
BACKGROUND Considerable discrepancies between Doppler and catheter gradients caused by localized gradients and pressure recovery have been reported for normal bileaflet aortic valve prostheses. METHODS AND RESULTS To examine whether this Doppler-catheter gradient relation is affected by prosthetic valve malfunction, a 19-mm CarboMedics aortic valve was simultaneously studied with continuous-w...
متن کاملContinuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valve...
متن کاملContinuous Wave Doppler Echocardiographic Measurement of Prosthetic Valve Gradients
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63+13 years) with 42 prosthetic valves (2...
متن کاملProgressive functional deterioration of bioprostheses assessed by Doppler ultrasonography.
Doppler echocardiography was used to study the function of bioprosthetic heart valves by noninvasive means in 32 patients aged 29 to 72 years at various postoperative intervals. There were 24 Ionescu-Shiley, four Hancock, and four Carpentier-Edwards prostheses, 19 in the aortic and 13 in the mitral position. Initial studies were performed at a mean of 2.3 years after implantation and were repea...
متن کاملAssessment of small-diameter aortic mechanical prostheses: physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation.
BACKGROUND Noninvasive assessment of functionally stenotic small-diameter aortic mechanical prostheses is complicated by theoretical constraints relating to the hemodynamic relevance of Doppler-derived transprosthetic gradients. To establish the utility of Doppler echocardiography for evaluation of these valves, 20-mm Medtronic Hall and 19-mm St Jude prostheses were studied in vitro and in vivo...