Radon Measurement Standards and Calibration

نویسندگان

  • J. M. R. Hutchinson
  • R. Collé
چکیده

This issue of the Journal of Research of the National Institute of Standards and Technology resulted from a one-half day seminar devoted to descriptions of the current status of the metrology of radon in international laboratories specializing in that area. The seminar, held June 5, 1989, at the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Federal Republic of Germany was co-sponsored by the Low-Level Measurement Techniques Group of the International Committee for Radionuclide Metrology (ICRM), the Commission of European Communities and the International Intercomparison and Intercalibration Program (HIP), now part of the International Atomic Energy Agency (IAEA). The HIP has spearheaded the international effort to standardize radon measurements. It has, in particular, conducted intercomparisons between four selected laboratories that perform radon calibrations on different instruments. These four laboratories, which presently serve as primary reference laboratories for separate geographical regions, are the Australian Radiation Laboratory, U.S. Department of Energy Environmental Measurements Laboratory, U.K. National Radiation Protection Board, and U.S. Department of Interior Bureau of Mines. In addition to these four laboratories, other contributors to this seminar included national standards laboratories— National Institute of Standards and Technology (NIST) and the Italian Committee for Research and Development of Nuclear and Alternative Energies (ENEA)—as well as four select laboratories that have studied important measurement techniques and calibration procedures. The seminar contributors were asked to describe their calibration measurement methods and in particular, to carefully assess and itemize their measurement uncertainties. A subsequent review, held in a workshop on the following day, established measurement needs and how present accuracies meet these needs. Often the user requires measurement accuracies in the 15-30 percent range. The quality assurance (QA) laboratories, such as the four primary HIP laboratories, should therefore have uncertainties approximately one third of this—say 5-10 percent. The metrology laboratories of the ICRM are required to establish national and international standards of radon for the QA laboratories. One expects from this that for the national metrology laboratories to make a significant contribution to the radioactivity metrology of radon gas, their uncertainties should be significantly below 5 percent—a reasonable objective would be on the order of 2-3 percent. The described methods are basically ionization chamber and scintillation cell measurements of gaseous ^^^Rn samples and gamma-ray measurements of the "^Rn daughters. The common standard is the NIST "^Ra standard, so that the various caUbration measurements are tests of the ability of the laboratories to transfer the same calibrations (NIST standard) to an unknown using different techniques. Generally speaking, the QA laboratories have reached their goal of accuracies of 5-10 percent. There are, however, discrepancies and inconsistencies in the intercomparisons at present which may be significant. These and other related topics are discussed in these proceedings. We are grateful to Drs. Debertin and Schrader and their staff at the PTB for making their facilities available and for being exemplary hosts. We are also grateful to Drs. Robert Holub, Earl Knutson, and Wayne Lower for their efforts in preparing the format of the meeting and helping contact the participants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The NIST Primary Radon-222 Measurement System

Within the United States, the national standard for radon measurements is embodied in a primary radon measurement system that has been maintained for over 50 years to accurately measure radon (222Rn) against international and national radium (226Ra) standards. In turn, all of the radon measurements made at the National Institute of Standards and Technology (NIST) and the radon transfer calibrat...

متن کامل

Radon monitor calibration using NIST radon emanation standards: steady flow method.

The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....

متن کامل

Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

Calibration of Electret-Based Integral Radon Monitors Using NIST Polyethylene-Encapsulated 226Ra/222Rn Emanation (PERE) Standards

The recently developed 222Rn emanation standards that are based on polyethylene-encapsulated 226Ra solutions were employed for a first field-measurement application test to demonstrate their efficacy in calibrating passive integral radon monitors. The performance of the capsules was evaluated with respect to the calibration needs of electret ionization chambers (E-PERM®, Rad Elec Inc.). The enc...

متن کامل

Nist Traceable Radon Calibration System for Calibrating

The NIST (National Institute of Standards and Technology) has recently made available 222Rn emanation standards for test and evaluation. The NIST certified parameters include the ^ ~ a strength and the emanation coefficient. When such a source is loaded into a radon leak tight enclosure of a known volume, 222~n accumulates over time and it is possible to calculate precisely the time integrated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -