In vitro assessment of an ultrasonic flowmeter for use in ventilated infants.

نویسندگان

  • P Scalfaro
  • J Cotting
  • P D Sly
چکیده

An ultrasonic flowmeter could be advantageous over a differential pressure pneumotachograph having a constant error in varying conditions. The in vitro accuracy of ultrasonic tidal volume (VT) estimates for ventilated infants were evaluated. Flow linearity and frequency response were tested, as was the influence of humidity and oxygen content on the accuracy of VT estimates. The linearity was within the 5% limits between -350 and 350 mL x sec(-1) and was not affected by the presence of an endotracheal tube (ET). The frequency response was flat and unaffected by an ET up to 4.5 Hz. The VT in the range 7-100 mL, in air showed a mean error of 0.1% (95% confidence interval (CI) -0.2-0.4%) with a maximum and minimum of 6.5 and -3.5% respectively. Humidity did not affect accuracy. After calibration in air, the maximal mean error for measurements in pure oxygen was 3.0% (95% CI 1.9-4.1%). Repeated measurements over 5.5 h had a mean error of 0.4% (95% CI -0.7-0.1%). The in vitro evaluation of an ultrasonic flowmeter showed stable accuracy in mechanical ventilation conditions. Changing connection geometry and oxygen content did not increase the error to a clinically relevant degree. The flowmeter could therefore be a better alternative than the pneumotachograph for ventilated infants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Piezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter

Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...

متن کامل

Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease.

AIMS To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease. METHODS Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n = 10), each infant was given 200 micrograms of salbutamol at 4 hour intervals and in random sequence from a me...

متن کامل

Assessment of ultrasound irradiation on inactivation of gram negative and positive bacteria isolated from hospital in aqueous solution

Microbial contamination of water poses a major threat to public health. With the emergence of microorganisms resistant to multiple antimicrobial agents, there is increased request for promotion of disinfection methods. Since ultrasound wave (US) exhibits antibacterial activities on bacteria, the aim of this study was to evaluate the antimicrobial effect of low frequency (37 kHz) ultrasound on P...

متن کامل

A Review of Assessment Tools for Oral Feeding in Term and Preterm Infants

Background and purpose: Problems in oral feeding are common in infants, especially in preterm infants. Therefore, assessment of infants feeding could be of great help in making appropriate diagnosis for rehabilitation of swallowing. Therefore, comprehensive and accurate assessment tools are needed. The aim of this study was to review assessment tools used for infants oral feeding. Materials an...

متن کامل

Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites

The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2000